3T BOLD MRI with low intrascan variability and high reproducibility of limb oxygenation measurements
نویسندگان
چکیده
Background Current imaging methods, including BOLD MR imaging, cannot reliably quantify muscle oxygenation in patients with limb ischaemia. The BOLD response is complex and measurements have so far been performed in relatively low-resolution EPI-readout images where it may be difficult to exclude oxygenation changes from partial volume effects. The reproducibility of BOLD imaging has been low and consequently its usefulness as a clinical test has been limited. We propose a high-resolution BOLD sequence whereby edge artefacts and vessels may be excluded from measurements, analysed using a Maximum Likelihood Estimate with Rician noise correction, where noise is read in k-space, for a precise and unbiased estimation of T2* from magnitude images. We test the hypothesis that this gives high reproducibility at baseline, and during and after transient ischaemia.
منابع مشابه
Retinotopic mapping with spin echo BOLD at 7T.
For blood oxygenation level-dependent (BOLD) functional MRI experiments, contrast-to-noise ratio (CNR) increases with increasing field strength for both gradient echo (GE) and spin echo (SE) BOLD techniques. However, susceptibility artifacts and nonuniform coil sensitivity profiles complicate large field-of-view fMRI experiments (e.g., experiments covering multiple visual areas instead of focus...
متن کاملReproducibility of quantitative structural and physiological MRI measurements
INTRODUCTION Quantitative longitudinal magnetic resonance imaging and spectroscopy (MRI/S) is used to assess progress of brain disorders and treatment effects. Understanding the significance of MRI/S changes requires knowledge of the inherent technical and physiological consistency of these measurements. This longitudinal study examined the variance and reproducibility of commonly used quantita...
متن کاملRegional reproducibility of calibrated BOLD functional MRI: Implications for the study of cognition and plasticity
Calibrated BOLD fMRI is a promising alternative to the classic BOLD contrast due to its reduced venous sensitivity and greater physiological specificity. The delayed adoption of this technique for cognitive studies may stem partly from a lack of information on the reproducibility of these measures in the context of cognitive tasks. In this study we have explored the applicability and reproducib...
متن کاملMultisite fMRI reproducibility of a motor task using identical MR systems.
PURPOSE To estimate between-scanner functional MRI (fMRI) reproducibility in a multisite study. MATERIALS AND METHODS A total of five identical 1.5T MR systems were used to repeatedly scan five subjects while performing a finger tapping task. A two-way (scanners, subjects) random effects analysis of variance (ANOVA) was used to estimate between-scanner and between-subject variability on two o...
متن کاملIncreasing the Spatial Resolution of 3T Carotid MRI Has No Beneficial Effect for Plaque Component Measurement Reproducibility
PURPOSE Different in-plane resolutions have been used for carotid 3T MRI. We compared the reproducibility, as well as the within- and between reader variability of high and routinely used spatial resolution in scans of patients with atherosclerotic carotid artery disease. Since no consensus exists about the optimal segmentation method, we analysed all imaging data using two different segmentati...
متن کامل