A comparison of the tensile and bending properties of dental gold wires.

نویسندگان

  • D F TAYLOR
  • F A PEYTON
چکیده

M ODERN dental practice makes wide use of precious metal alloys in wire form as partial denture clasps and as orthodontic appliances. When used in such applications, these alloys are subject only to bend loading and never to pure tensile loading. For this reason, there has long been a feeling within the dental profession that the tensile test for wires was somewhat inappropriate and might be replaced advantageously by a bend test. However, the absence of any previous correlation between the test values obtained from the two types of loading, as well as the large amount of effort represented by collected tensile data on these alloys, has heretofore prevented any serious consideration of a possible change of standards from one test to the other. The technical representatives of several manufacturers have displayed a continuing interest in the development of possible relationships between tension and bend tests. This interest was expressed through the loan, by these manufacturers, of gold alloy wires of high intrinsic value for use in this investigation. Further support was received from the Office of Naval Research which sponsored the project as a part of its program of research on the properties of restorative dental materials. The specific purpose of this investigation was to determine what correlation, if any, existed between the mechanical properties of wrought gold alloys as found in a standard tensile test and those as found in a bend test. The type of bend test used in this investigation was the cantilever loading of a wrought gold wire. It is believed that the conditions of such a bend test much more nearly approach the actual conditions under which these alloys are used than does the tensile test. The program of the project was set up as follows: An attempt was made to obtain a wide range of inherent mechanical properties in the alloys to be tested, at the same time reducing as far as possible other variables such as wire size, sample length, and heat treatment. A total of twelve alloys was selected, all of the same size and all to be subjected to identical heat treatment and testing. These alloys were to be tested in two conditions, fully soft (10 min. at 7000 C., quench), and age hardened (softened as above, then 15 min. at 360° C.). It was recognized that this hardening practice might not produce either the maximum or optimum properties of any one alloy, but it was

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of section size on the mechanical properties of wrought gold wires.

R ESULTS of tensile tests made with the nonprecious metals, notably aluminum, have proved that section size is not a factor in determining proportional limit, provided the grain size is not excessive.' However, these tests were made on specimens varying from 0.500 to 0.050 inches in diameter, and wrought dental gold wires, in which the diameter is as small as 0.030 inches, are often used. It is...

متن کامل

Evaluating the Semi-Circular Bending Test for HMA Mixtures

Semi-Circular Bending (SCB) Test is a fast and accurate three-point bending test, which was originally used in rock mechanics. SCB test is going to be an accepted test method for asphalt concrete pavements. Different asphalt-mixture property-values such as tensile strength, stress intensity factor and fatigue can be obtained by this test. In this study, static and dynamic tests including SCB te...

متن کامل

In-vitro Investigations of Skin Closure using Diode Laser and Protein Solder Containing Gold Nanoshells

Introduction: Laser tissue soldering is a new technique for repair of various tissues including the skin, liver, articular cartilage and nerves and is a promising alternative to suture. To overcome the problems of thermal damage to surrounding tissues and low laser penetration depth, some exogenous chromophores such as gold nanoshells, a new class of nanoparticles consisting of a dielectric cor...

متن کامل

بررسی و مقایسه اثرات عملیات حرارتی RRA، T73 و T6 بر سختی، استحکام کششی و خمشی آلیاژ آلومینیم 7075

In the present article, RRA, T73 and T6 heat treatments were carried out to improve mechanical properties of 7075 aluminum alloy and its hardness, tensile and bending strengths were evaluated. For this purpose, solution annealing was performed at 530 ºC for 16 h. For T6 treatment, aging was executed at 150 ºC for 24 h after solution annealing. In T73, aging treatment was done in two s...

متن کامل

A Comparative Evaluation of Effects of Different Kinds of Sterilizations on Load Deflection Characteristics, Tensile Properties of Copper Niti Wires- an Invitro Study

Copper NiTi wires were introduced by Sachdeva R and Miyasaki S in 1994. This latest innovation in the evolutionary scale gives us the opportunity of choosing the force level by choosing the temperature at which the wires will deliver its optimum force level. With so many advantages and their ability to return to their original form coupled with the high cost of copper NiTi many clinicians start...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of dental research

دوره 30 2  شماره 

صفحات  -

تاریخ انتشار 1951