The effect of low-intensity therapeutic ultrasound in induced fracture of rat tibiae
نویسندگان
چکیده
OBJECTIVE To analyze the possible effects of low-intensity ultrasound on induced tibia fracture of rats in a dose commonly used in physical therapy treatments. METHODS Twenty male Wistar rats were divided into two groups with 10 animals each. In the ultrasound group (USG), the animals were submitted to bone fracture and treatment with therapeutic ultrasound (TUS). Ultrasonic parameters are: frequency of 1.0 MHz, intensity of 0.2 W/cm2, pulsed mode at 20%, applied in stationary form during 10 minutes on the fracture region, for five weeks. The control group (CG) was submitted to bone fracture but not treated with ultrasound. RESULTS The radiographies showed better consolidation in USG compared to CG. The statistical tests for alkaline phosphatase and serum calcium did not show significant difference between groups. CONCLUSION According to this study, TUS, applied with these parameters (not commonly used for bone therapy) accelerates bone healing, confirmed by radiography, yet the biochemical analysis was not conclusive. One reason for this inconsistency may have been some inadequacy of the biochemical protocol, currently under investigation. Level of Evidence II, Prospective comparative study.
منابع مشابه
بررسی اثر امواج اولتراسوند منقطع با فرکانس پایین بر تشکیل کال استخوانی تیبیا در خرگوش( ارزیابی رادیولوژیک و بیومکانیک)
Background and Objective: Application of low intensity ultrasound has been used for treatment of many diseases in medicine and has suggested for accelerating wound healing process, modifying scar tissue and relief of pain. The aim of this study was radiological and biomechanical evaluation of low-intensity pulsed ultrasound on callus formation of tibia in rabbit. Materials and Methods: In this...
متن کاملLOW INTENSITY PULSED ULTRASOUND TREATMENT INCREASES RABBIT RADIAL FRACTURE HEALING
In order to study the effect of ultrasound (US) on bone healing, a complete transverse fracture was made in the right radius of adult male rabbits by a cutter. 52 rabbits were used: group I. control (n= 17): group 2. test (n:=: 15): group 3, intact (n= I) and group 4 (n= 12) who were examined only for evaluation of the cutter effects in detail. 7 animals were operated with a Gigli saw. The ...
متن کاملTHE BEST DURATION OF LOW INTENSITY PULSED ULTRASOUND FOR ACCELERATING FRACTURED-RADIAL BONE REPAIR
We have already shown that low intensity pulsed ultrasonic treatment increases rabbit radial fracture healing. The present experiment was undertaken to find out the best duration for treatment. A complete transverse fracture was made in the right radial bones of21 adult male rabbits by a Stanley knife. The animals were divided into 4 groups: group 1, control groups 2, 3, and 4, experimental...
متن کاملEffects of Low-Level Helium-Neon Laser Therapy on Healing of Partial Thickness Defect of Experimental Induced Diabetic Rats
Purpose: The aim of present study was to study the effects of low-level helium–neon laser irradiation on biomechanical properties of tibiae partial bone defect in streptozotocin–diabetic rat. Materials and Methods: Twenty male rats were used .Diabetes was induced in rats by one time intraperitoneal injection of 60 mg/kg streptozotocin .After one month ,under sterile conditions and general anes...
متن کاملFree hydroxyl radical dosimetry by using 1 MHz low level ultrasound waves
ABSTRACTBackground : In order to quantify effects of ultrasound irradiation parameters under therapeutic condition, especially sonodynamic therapy, it is initially necessary to evaluate inertial cavitation activity in vitro conditions therefore, in this study, the effect of 1 MHz low level ultrasound based on °OH radicals generated by acoustic inertial cavitation in aqueous solution was monit...