Recommendation to include fragrance mix 2 and hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) in the European baseline patch test series.
نویسندگان
چکیده
BACKGROUND The currently used fragrance mix in the European baseline patch test series (baseline series) fails to detect a substantial number of clinically relevant fragrance allergies. OBJECTIVE To investigate whether it is justified to include hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) and fragrance mix 2 containing hydroxyisohexyl 3-cyclohexene carboxaldehyde, citral, farnesol, coumarin, citronellol, and alpha-hexyl cinnamal in the European baseline patch test series. METHODS Survey of the literature on reported frequencies of contact allergy and allergic contact dermatitis from fragrance mix 2 and hydroxyisohexyl 3-cyclohexene carboxaldehyde (Lyral) as well as reported results of experimental provocation test. RESULTS Fragrance mix 2 has been demonstrated to be a useful additional marker of fragrance allergy with contact allergy rates up to 5% when included in various national baseline patch test series. Of the fragrance substances present in fragrance mix 2, hydroxyisohexyl 3-cyclohexene carboxaldehyde is the most common sensitizer. Contact allergy rates between 1.5% and 3% have been reported for hydroxyisohexyl 3-cyclohexene carboxaldehyde in petrolatum (pet.) at 5% from various European centres when tested in consecutive dermatitis patients. CONCLUSIONS From 2008, pet. preparations of fragrance mix 2 at 14% w/w (5.6 mg/cm(2)) and hydroxyisohexyl 3-cyclohexene carboxaldehyde at 5% w/w (2.0 mg/cm(2)) are recommended for inclusion in the baseline series. With the Finn Chamber technique, a dose of 20 mg pet. preparation is recommended. Whenever there is a positive reaction to fragrance mix 2, additional patch testing with the 6 ingredients, 5 if there are simultaneous positive reactions to hydroxyisohexyl 3-cyclohexene carboxaldehyde and fragrance mix 2, is recommended.
منابع مشابه
Patch testing with fragrance mix II: results of the IVDK 2005-2008.
BACKGROUND The fragrance mix (FM I), established in 1977, detects the majority, but not all cases of contact allergy to fragrances. Based on European research 2002/2003, fragrance mix II (FM II) was developed to supplement FM I. In 2005, the German Contact Dermatitis Research Group (DKG) added FM II to their baseline series. OBJECTIVES To evaluate reactions to FM II and its constituents in ro...
متن کاملFragrance contact allergy: a 4-year retrospective study.
BACKGROUND Fragrance chemicals are the second most frequent cause of contact allergy. The mandatory labelling of 26 fragrance chemicals when present in cosmetics has facilitated management of patients allergic to fragrances. OBJECTIVES The study was aimed to define the characteristics of the population allergic to perfumes detected in our hospital district, to determine the usefulness of mark...
متن کاملFragrance mix II in the baseline series contributes significantly to detection of fragrance allergy.
BACKGROUND Fragrance mix II (FM II) is a relatively new screening marker for fragrance contact allergy. It was introduced in the patch test baseline series in Denmark in 2005 and contains six different fragrance chemicals commonly present in cosmetic products and which are known allergens. AIM To investigate the diagnostic contribution of including FM II in the baseline series by comparing it...
متن کاملRisk factors associated with sensitization to hydroxyisohexyl 3-cyclohexene carboxaldehyde.
BACKGROUND Hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC) is a synthetic fragrance chemical and an important contact allergen, at least in Europe. Despite this importance, little is known about risk factors associated with this allergen. OBJECTIVE To examine factors from the history and clinical presentation of patch tested patients associated with HICC sensitization. METHODS Contact a...
متن کاملMulticentre patch testing with fragrance mix II and hydroxyisohexyl 3-cyclohexene carboxaldehyde by the Swedish Contact Dermatitis Research Group.
Marléne Isaksson1, Annica Inerot2, Carola Lidén3,4, Magnus Lindberg5, Mihaly Matura3,4, Halvor Möller1, Berndt Stenberg6 and Magnus Bruze1 1Department of Occupational and Environmental Dermatology, Skåne University Hospital, Lund University, Malmö SE-205 02, Sweden, 2Department of Dermatology, Sahlgrenska University Hospital, Gothenburg SE-413 45, Sweden, 3 Institute of Environmental Medicine, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Contact dermatitis
دوره 58 3 شماره
صفحات -
تاریخ انتشار 2008