Clinical Use of 3D Printing Guide Plate in Posterior Lumbar Pedicle Screw Fixation.
نویسندگان
چکیده
BACKGROUND This study aimed to evaluate the clinical efficacy of use of a 3D printing guide plate in posterior lumbar pedicle screw fixation. MATERIAL AND METHODS We enrolled 43 patients receiving posterior lumbar pedicle screw fixation. The experimental group underwent 3D printing guide plate-assisted posterior lumbar pedicle screw fixation, while the control group underwent traditional x-ray-assisted posterior lumbar pedicle screw fixation. After surgery, CT scanning was done to evaluate the accuracy of screw placement according to the Richter standard. RESULTS All patients were followed up for 1 month. The mean time of placement for each screw and the amount of hemorrhage was 4.9±2.1 min and 8.0±11.1 mL in the experimental group while 6.5±2.2 min and 59.9±13.0 mL in the control group, respectively, with significant differences (p<0.05). The fluoroscopy times of each screw placement was 0.5±0.4 in the experimental group, which was significantly lower than that in the control group 1.2±0.7 (p<0.05). The excellent and good screw placement rate was 100% in the experimental group and 98.4% in the control group, without any statistical difference (P>0.05). No obvious complications were reported in either group. CONCLUSIONS Compared with the traditional treatment methods, the intra-operative application of 3D printing guide plate can shorten the operation time and reduce the amount of hemorrhage. It can also reduce the fluoroscopy times compared with the traditional fluoroscopy, which cannot improve the accuracy rate of screw placement.
منابع مشابه
Finite Element Analysis of a New Pedicle Screw-Plate System for Minimally Invasive Transforaminal Lumbar Interbody Fusion
PURPOSE Minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) is increasingly popular for the surgical treatment of degenerative lumbar disc diseases. The constructs intended for segmental stability are varied in MI-TLIF. We adopted finite element (FE) analysis to compare the stability after different construct fixations using interbody cage with posterior pedicle screw-rod or ped...
متن کاملSegmental Stiffness Achieved by Three Types of Fixation for Unstable Lumbar Spondylolytic Motion Segments
Objective The objective of this study was to compare the relative stability in lumbar spondylolysis (SP) of a rigid anterior plate (with a novel compression slot) versus traditional posterior pedicle screw (PS) fixation. Summary of Background Data Arthrodesis has been a mainstay of treatment for symptomatic isthmic spondylolisthesis in adults. Posterior PS fixation has become a commonly used ad...
متن کاملIndividualized 3D printing navigation template for pedicle screw fixation in upper cervical spine
PURPOSE Pedicle screw fixation in the upper cervical spine is a difficult and high-risk procedure. The screw is difficult to place rapidly and accurately, and can lead to serious injury of spinal cord or vertebral artery. The aim of this study was to design an individualized 3D printing navigation template for pedicle screw fixation in the upper cervical spine. METHODS Using CT thin slices da...
متن کاملThoracic Pedicle Screw Placement Guide Plate Produced by Three-Dimensional (3-D) Laser Printing
BACKGROUND The aim of this study was to evaluate the accuracy and feasibility of an individualized thoracic pedicle screw placement guide plate produced by 3-D laser printing. MATERIAL AND METHODS Thoracic pedicle samples of 3 adult cadavers were randomly assigned for 3-D CT scans. The 3-D thoracic models were established by using medical Mimics software, and a screw path was designed with scan...
متن کاملBiomechanical analysis of differing pedicle screw insertion angles.
BACKGROUND Pedicle screw fixation to stabilize lumbar spinal fusion has become the gold standard for posterior stabilization. A significant percentage of surgical candidates are classified as obese or morbidly obese. For these patients, the depth of the incisions and soft tissue makes it extremely difficult to insert pedicle screws along the pedicle axis. As such, the pedicle screws can only be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical science monitor : international medical journal of experimental and clinical research
دوره 21 شماره
صفحات -
تاریخ انتشار 2015