Usefulness of frequency doubling technology perimetry 24-2 in glaucoma with parafoveal scotoma

نویسندگان

  • Kyoung In Jung
  • Eun Kyoung Kim
  • Chan Kee Park
چکیده

The standard automated perimetry (SAP) 24-2 test cannot adequately test the paracentral region because test points are located sparsely in macular area where is crowded with retinal ganglion cells (RGCs), even though paracentral scotoma is clinically related to a risk of losing visual function. More sensitive visual field (VF) tests are needed to assess paracentral VF defects precisely. We investigated the structure-function relationship on the SAP 10-2 test and the frequency doubling technology (FDT) 24-2 test as well as the SAP 24-2 test in glaucoma with parafoveal scotoma (PFS). Glaucoma patients with PFS (134 patients) were included in this cross-sectional study. Sub-analysis was performed with isolated PFS (51 patients). Global and sectoral mean sensitivities (MS) were evaluated using SAP 24-2, 10-2, and FDT 24-2 program. MS was analyzed as dB or unlogged 1/lambert (SAP) or 1/Michelson contrast (FDT). Ganglion cell-inner plexiform layer (GCIPL) thickness was measured using spectral domain optical coherence tomography. Topographic relationships between the structure and the function were analyzed. In the total PFS group, good structure-function correlations were found in all zones with SAP 24-2, 10-2, and FDT 24-2 test. For glaucoma with isolated PFS, average GCIPL thickness was significantly correlated with central cluster MS (dB) using the SAP 10-2 test (r = 0.279, P = .047) and the FDT 24-2 test (r = 0.289, P = .039), but not the SAP 24-2 test (r = 0.264, P = .061). Topographically, the FDT 24-2 test showed significant correlations in all sectors between sectoral MS and corresponding GCIPL thickness. With regard to the SAP 10-2 test, there was significant topographical structure-function correlations for the superotemporal, inferotemporal, and inferonasal sectors. For SAP 24-2, only inferonasal GCIPL thickness was correlated with the corresponding VF sensitivity. Topographical structure-function on the macula was better with the SAP 10-2 test (superotemporal sector) and the FDT 24-2 test (superotemporal sector) than with the SAP 24-2 test in glaucoma with isolated PFS. In conclusion, FDT 24-2 and SAP 10-2 tests performed more favorably than the SAP 24-2 test in the structure-function relationship of glaucoma patients with isolated paracentral scotoma. FDT 24-2 tests can be another good option for detecting and monitoring RGC loss on the macular area while not missing VF defects outside the central 10°.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Structure–Function Relationship in Glaucoma Patients With Parafoveal Versus Peripheral Nasal Scotoma

PURPOSE We evaluated whether the structure-function relationship in glaucoma patients with parafoveal scotoma or peripheral scotoma differs with the use of frequency doubling technology (FDT) or short-wavelength automated perimetry (SWAP) compared to standard automated perimetry (SAP). METHODS Glaucoma patients with isolated parafoveal scotoma (PFS) within the central 10° of fixation in 1 hem...

متن کامل

Screening for glaucoma with frequency-doubling technology and Damato campimetry.

OBJECTIVE To assess frequency-doubling technology (FDT) perimetry (Humphrey Systems, San Leandro, Calif) and Damato campimetry (Precision Vision, Villa Park, Ill) for detecting glaucoma in a public glaucoma screening. METHODS A 2-day public glaucoma screening was held at 2 different institutions. Each subject underwent 2 visual field screening tests (Damato campimetry and FDT perimetry in scr...

متن کامل

Agreement between frequency doubling perimetry and static perimetry in eyes with high tension glaucoma and normal tension glaucoma.

AIMS To investigate the agreement in results between frequency doubling technology (FDT) and the conventional automated static perimeter in eyes with normal tension glaucoma (NTG) and high tension glaucoma (HTG). METHODS 72 eyes of 36 patients, who had two or more experiences with the Humphrey field analyser (HFA) program C30-2, were examined with the screening C-20-1 program of FDT. The resu...

متن کامل

CLINICAL SCIENCE Agreement between frequency doubling perimetry and static perimetry in eyes with high tension glaucoma and normal tension glaucoma

Aims: To investigate the agreement in results between frequency doubling technology (FDT) and the conventional automated static perimeter in eyes with normal tension glaucoma (NTG) and high tension glaucoma (HTG). Methods: 72 eyes of 36 patients, who had two or more experiences with the Humphrey field analyser (HFA) program C30-2, were examined with the screening C-20-1 program of FDT. The resu...

متن کامل

Clinical evaluation of frequency doubling technology perimetry using the Humphrey Matrix 24-2 threshold strategy.

AIMS To evaluate performance of frequency doubling technology (FDT) perimetry using the Humphrey Matrix 24-2 thresholding program in a hospital eye service (HES) glaucoma clinic. METHODS A random sample of individuals referred consecutively to the HES for suspected glaucoma were examined with 24-2 threshold FDT in addition to routine clinical tests. The discriminatory power of FDT and standar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 96  شماره 

صفحات  -

تاریخ انتشار 2017