New photometric calibration programmes at the National Institute of Standards and Technology
نویسندگان
چکیده
The National Institute of Standards and Technology (NIST) candela is maintained via standard photometers which have shown long-term stability of better than 0.1 % per year. The detector-based method has allowed us to reduce the uncertainties of calibrations and to expand the range of calibration capabilities. There have been several new developments in photometry at the NIST. A high-illuminance calibration facility has been developed. Four temperature-controlled standard photometers, tested for linearity and thermal effects at high illuminances, are used with a high-pressure xenon arc source to provide the illuminance scale at levels up to 100 klx. A flashing-light photometric unit (lx s) has been realized using four standard photometers equipped with current integrators, and using two independent methods. Calibration services for illuminance meters at high illuminance levels and flashing-light photometers are now available at the NIST. Ongoing new projects include the development of a detector-based luminous-flux calibration facility using a 2.5 m integrating sphere, realization of the total spectral radiant-flux scale, and the development of a reference spectroradiometer for colorimetry of displays. Calibration services are planned in these areas of photometry and colorimetry in the near future.
منابع مشابه
New Photometric Calibration Programs at the National Institute of Standards and Technology
The NIST candela is maintained via standard photometers which have shown long-term stability better than 0.1% per year. The detector-based method has allowed us to reduce the uncertainties of calibrations and to expand the range of calibration capabilities. There have been several new developments in photometry at NIST. A high-illuminance calibration facility has been developed. Four temperatur...
متن کاملCalibration method of numerical models in coastal sediment studies of Kuhmobarak area
Abstract Application of numerical models is useful in coastal sediment studies; however, it is essential to calibrate the models in an appropriate method. Empirical equations, historical satellite imagery and other coastal data and evidence are proposed for the models calibration in the vicinity of coastal indicators around the site of projects. In this study, coastal sediment process of K...
متن کاملImproved Photometric Standards and Calibration Procedures at NIST
NIST has recently established a detector-based luminous intensity unit (candela, cd), which is derived from the NIST absolute cryogenic radiometer. Subsequently, the luminous flux unit (lumen, lm) and the luminance unit (cd/m2) have been established based on the detector-based candela, and now all the NIST photometric units are tied to the cryogenic radiometer. The illuminance unit is realized ...
متن کاملUncertainty in NIST Force Measurements
This paper focuses upon the uncertainty of force calibration measurements at the National Institute of Standards and Technology (NIST). The uncertainty of the realization of force for the national deadweight force standards at NIST is discussed, as well as the uncertainties associated with NIST's voltage-ratio measuring instruments and with the characteristics of transducers being calibrated. T...
متن کاملThe NIST Primary Radon-222 Measurement System
Within the United States, the national standard for radon measurements is embodied in a primary radon measurement system that has been maintained for over 50 years to accurately measure radon (222Rn) against international and national radium (226Ra) standards. In turn, all of the radon measurements made at the National Institute of Standards and Technology (NIST) and the radon transfer calibrat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -