3D Double Echo TrueFISP and FLASH Ultra-short Echo Time Musculoskeletal Imaging
نویسندگان
چکیده
Introduction Ultra-short Echo Time (UTE) MRI allows for the detection of short T2 components (T2 of the order of 100 μs) in tissue before they have decayed [1, 2]. This is potentially interesting for a range of applications such as MR imaging of bone, tendons and ligaments, sodium MRI, and other applications such as MR-PET attenuation correction. Until now the UTE method has been based on a Steady State Free Precession (SSFP) sequence with Fast Low Angle Shot (FLASH) contrast [2] where, an excitation pulse α tips the magnetization M0 so that the transverse component Mt=M0sinα can be measured and, after the readout gradient, is spoiled through gradient and RF spoiling, so that only the longitudinal component Ml=M0cosα is available for the next excitation. This FLASH technique suffers from two main disadvantages: low signal-to-noise ratio (SNR) and low contrast. These two drawbacks, together with the fact that the ultra short T2 signal is intrinsically low, compromise the image quality and diagnostic relevance of this technique. Balanced Steady State Free Precession (b-SSFP, also known as TrueFISP, FIESTA, and balanced FFE) [4, 5] is an SSFP technique in which the magnetization Mt is preserved by applying fully compensated gradients that null the zeroth moment between RF-pulses. TrueFISP provides a different contrast and higher SNR and, due to the fact that the gradients are fully compensated, TrueFISP is inherently less sensitive to eddy currents than FLASH. The UTE signal decays with ultra-short T2. This means that, for TrueFISP acquisitions, Mt will only be preserved from RF excitation to RF excitation if the repetition time (TR) is very short (TR≤T2). Therefore, as long as TR>T2, the behavior and intensity of the UTE signal should be identical for TrueFISP and FLASH acquisitions. On the other hand, fast readouts are required to better describe the UTE signal decay. For such high bandwidths (BW) and short TRs, TrueFISP images will have a sharper point-spread-function than FLASH images due to their insensitivity to eddy currents, leading to increased SNR. Materials and Methods The 3D radial multi-echo UTE sequence and reconstruction algorithm were implemented on a 1.5 T clinical scanner (MAGNETOM Avanto, Siemens AG HCS, Erlangen, Germany). It consists of a 60μs long non-selective RF pulse followed by a 40μs transmit/receive switch time and a 100% asymmetric data acquisition from the centre to the surface of a sphere. In order to achieve the shortest possible TE, data acquisition starts during ramp-up time of the readout gradient. The online reconstruction program consists of a Kaiser-Bessel Gridding algorithm (window width = 3 and β = 4.2054) with sampling density compensation modified to correct for undersampling. Foam phantom experiments were performed to determine the SNR increase between FLASH and TrueFISP for the same sequence parameters (TR = 3.1 ms, TE=0.07, α = 15°, BW = 5210 Hz/pixel). The following sequence parameters were used for volunteer examinations of the head: TR = 4.1 ms, double echo TE=0.07 and 2.67 ms, α = 15°, BW = 1149 Hz/pixel, 64000 projections, Tacq= 4 min).
منابع مشابه
Navigator-Gated Whole Heart Coronary MRI with 3D isotropic Double Echo TrueFISP UTE
Introduction Coronary MRA provides a non-invasive approach for the detection of coronary artery disease. Previous works have shown that whole heart 3D radial techniques simplify the scanning procedure with no compromise in image quality [1-4]. Ultra-short Echo Time (UTE) MRI allows for the detection of short T2 components (T2 of the order of 100 μs) in tissue before they have decayed [5, 6]. Th...
متن کاملComparison of Three-Dimensional Double-Echo Steady-State Sequence with Routine Two-Dimensional Sequence in the Depiction of Knee Cartilage
Introduction: There are some routine two-dimensional sequences, including short tau inversion recovery (STIR), T2-weighted fast-spin echo (T2W-FSE), and proton-density fast spin-echo for diagnosing osteoarthritis and lesions of the knee cartilage. However, these sequences have some disadvantages, such as long scan time, inadequate spatial resolution, and suboptimal tis...
متن کاملMR temperature measurement in liver tissue at 0.23 T with a steady-state free precession sequence.
MRI can be used for monitoring temperature during a thermocoagulation treatment of tumors. The aim of this study was to demonstrate the suitability of a 3D steady-state free precession sequence (3D Fast Imaging with Steady-State Precession, 3D TrueFISP) for MR temperature measurement at 0.23 T, and to compare it to the spin-echo (SE) and spoiled 3D gradient-echo (3D GRE) sequences. The optimal ...
متن کاملComparing Relative Contrast in Three-dimensional Double-echo Steady State With Routine Sequences for a Better Diagnosis of Knee Cartilage Anomalies
Aims This study compared relative contrast values in three-dimensional Double Echo Steady State (DESS) sequences with two flip angles of 40 and 90 degrees and other routine sequences. The obtained data could help to prove the effects of this sequence, compared to the other routine sequences; accordingly, it could be applied for better detection of lesions resulting from cartilage abnormalities....
متن کاملSodium Mri of Articular Cartilage with Improved Snr Using Coherent Ssfp Imaging at 7t
PURPOSE: Sodium (Na) MRI offers direct information on the glycosaminoglycan concentration in cartilage. In vivo Na-MRI, however, is very challenging because of low Na sensitivity, low tissue concentration, and short biexponential transverse relaxation times (T2). Sequences capable of maximizing signal-to-noise ratio (SNR) are therefore highly desirable. Many groups addressed this issue by devel...
متن کامل