A Novel Anti-interference Method for Partial Discharges On-line Measurement of Hv Power Cables

نویسندگان

  • Wenjie LI
  • Junhua LUO
  • Jiankang ZHAO
  • Shaoxin MENG
  • Rong XIA
  • Xuejin ZHANG
  • Leilei PAN
چکیده

In order to extract the millivolt range partial discharge(PD) signals drown in the harsh electromagnetic interference for HV power cables, this paper presents a novel antiinterference method, based on fast fourier transform autothresholding method, 1-D discrete wavelet thresholding method and three phase amplitude and arrive-time difference method. This method is examined and proved to be effective on the power cable with actual interference. Moreover, the insulation condition assessment application of a 7.1km 220kV XLPE power cable line shows that the anti-interference effect is outstanding to eliminate field harsh interference, laying a good foundation for further PD pattern analysis and diagnosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-line Partial Discharge Monitoring System and Data Processing Using WTST-NST Filter for High Voltage Power Cable

Defects inside insulation of HV XLPE cable accessories can lead to partial discharge (PD) activity. When PD activity happens, leakage current may flow through the grounded line. To acquire the PD current signal, one practicable and effective method is placing a high frequency current transformer (HFCT) winding the grounded line. In order to measure the insulation degradation, a partial discharg...

متن کامل

Continuous On-line Condition Monitoring of HV Cable Systems

This paper discusses data acquisition, transmission and processing methodologies for continuous on-line monitoring of partial discharges in high voltage cable systems. A PD continuous on-line monitoring system for underground cable circuits using capacitive couplers, LiNbO3 electro-optic modulators, laser, optical switch and optical fibers has been developed. Future research will consider effec...

متن کامل

A novel calibration method for PD measurements in power cables and joints using capacitive couplers

Partial discharge (PD) measurements are universally accepted as a technique giving some indication of the state of the insulation in high-voltage apparatus. Cable end users are keen to adopt online PD monitoring during commissioning of systems. However, because of noisy environments and the problems of interference the conventional methods are difficult to implement. As a consequence, ultra-hig...

متن کامل

Advanced technique for partial discharge detection and analysis in power cables

Polymeric cables are the most common choice for transmission and distribution in populated areas, as well as for the connection of components (transformers, GIS, etc.) in new power stations, replacing paper-oil cables. Indeed, they do possess superior characteristics with respect to oil-filled cables. As an example, they do require lower maintenance, they are lighter (easier to deploy) and, in ...

متن کامل

Survey of De-noising Techniques for Partial Discharge Interferences

Partial Discharges (PD) are recognized as one of the main causes of degradation of internal insulation of power equipment and its subsequent failure in high voltage equipment. In most real-time applications such as extruded cables, Gas Insulated Substations (GIS) etc., polymeric insulation systems which invariably used. It is necessary and demand to detect even very low levels of PD pulse disch...