Estimating activity-related energy expenditure under sedentary conditions using a tri-axial seismic accelerometer.

نویسندگان

  • Vincent T van Hees
  • Rob C van Lummel
  • Klaas R Westerterp
چکیده

Activity-related energy expenditure (AEE) is difficult to quantify, especially under sedentary conditions. Here, a model was developed using the detected type of physical activity (PA) and movement intensity (MI), based on a tri-axial seismic accelerometer (DynaPort MiniMod; McRoberts B.V., The Hague, the Netherlands), with energy expenditure for PA as a reference. The relation between AEE (J/min/kg), MI, and the type of PA was determined for standardized PAs as performed in a laboratory including: lying, sitting, standing, and walking. AEE (J/min/kg) was calculated from total energy expenditure (TEE) and sleeping metabolic rate (SMR) as assessed with indirect calorimetry ((TEEx0.9)-SMR). Subsequently, the model was validated over 23-h intervals in a respiration chamber. Subjects were 15 healthy women (age: 22+/-2 years; BMI: 24.0+/-4.0 kg/m2). Predicted AEE in the chamber was significantly related to measured AEE both within (r2=0.81+/-0.06, P<0.00001) and between (r2=0.70, P<0.001) subjects. The explained variation in AEE by the model was higher than the explained variation by MI alone. This shows that a tri-axial seismic accelerometer is a valid tool for estimating AEE under sedentary conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimates of energy expenditure using the RT3 accelerometer in patients with systemic lupus erythematosus

This study aimed to characterize energy expenditure patterns using the tri-axial accelerometer and to identify the association of energy expenditure with clinical parameters in patients with systemic lupus erythematosus (SLE). Estimates of energy expenditures represented by total activity calorie (TA), physical activity calorie (PA), total activity calorie per body weight (TABW), and physical a...

متن کامل

Weight-Loss Induced Changes in Physical Activity and Activity Energy Expenditure in Overweight and Obese Subjects before and after Energy Restriction

Activity energy expenditure (AEE) is the component of daily energy expenditure that is mainly influenced by the amount of physical activity (PA) and by the weight of the body displaced. This study aimed at analyzing the effect of weight loss on PA and AEE. The body weight and PA of 66 overweight and obese subjects were measured at baseline and after 12 weeks of 67% energy restriction. PA was me...

متن کامل

Assessment of energy expenditure for physical activity using a triaxial accelerometer.

A triaxial accelerometer was used to evaluate the relationship between energy expenditure due to physical activity (EEact) and body acceleration during different types of activity. In a laboratory experiment, 11 male subjects performed sedentary activities and walked on a motor driven treadmill (3-7 km.h-1). EEact was calculated from total energy expenditure (EEtot), as measured by indirect cal...

متن کامل

Towards valid estimates of activity energy expenditure using an accelerometer: searching for a proper analytical strategy and big data.

ESTIMATING ENERGY EXPENDITURE and the metabolic response to physical activity are complex areas of research, manifested by the increasingly sophisticated instruments and methodologies being proposed in the literature. Wearable motion sensors, such as accelerometers, are the most widely studied tools to assess activity-related energy expenditure (AEE) by quantifying body movement. These two fund...

متن کامل

Physical activity recognition using a wearable accelerometer New perspectives for energy expenditure assessment and health promotion

The aim of this study was to investigate the ability of a novel activity monitor designed to be minimally obtrusive in predicting free-living energy expenditure. Subjects were 18 men and 12 women (age: 41 ± 11 y, BMI: 24.4 ± 3 kg/m). The habitual physical activity was monitored for 14 days using a DirectLife tri-axial accelerometer for movement registration (TracmorD) (Philips New Wellness Solu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Obesity

دوره 17 6  شماره 

صفحات  -

تاریخ انتشار 2009