Generation of tunable subpicosecond light pulses in the midinfrared between 4.5 and 11.5 microm.
نویسندگان
چکیده
Stable subpicosecond infrared pulses in the spectral region of 4.5-11.5 microm are generated by difference-frequency mixing in AgGaS(2). The system uses femtosecond pulses from a Ti:sapphire regenerative amplifier and from a tunable traveling-wave dye laser. The infrared pulses have a duration of 400 fs, an energy of more than 10 nJ, and a repetition rate of 1 kHz.
منابع مشابه
Widely tunable midinfrared difference frequency generation in orientation-patterned GaAs pumped with a femtosecond Tm-fiber system.
We demonstrate a midinfrared source tunable from 6.7 to 12.7 μm via difference frequency generation (DFG) in orientation-patterned GaAs, with 1.3 mW average output power. The input pulses are generated via Raman self-frequency shift of a femtosecond Tm-doped-fiber laser system in a fluoride fiber. We numerically model the DFG process and show good agreement between simulations and experiments. ...
متن کاملGeneration of a 20 GHz train of subpicosecond pulses with a stabilized optical-frequency-comb generator.
With a modulator-based 10 GHz optical-frequency-comb generator at 1.55 microm, we report a 20 GHz repetitive train of optical pulses as short as 450 fs. The timing stability of the 20 GHz pulses, in addition to the phase for optical-comb modes, shows a strong dependence on the relative frequency detuning between the comb generator's cavity and the seed cw laser. With a new and simple scheme, th...
متن کاملSubpicosecond-pulse generation through cross-phase-modulation-induced modulational instability in optical fibers.
We report subpicosecond-pulse generation at 1.319 microm in a single-mode optical fiber by modulational instability induced through cross-phase modulation by 1.06-microm pulses propagating in the normal dispersion regime. Pulse-repetition rates approaching 300 GHz were achieved.
متن کاملHighly sensitive multichannel spectrometer for subpicosecond spectroscopy in the midinfrared.
A spectrometer system is presented for time-resolved probing in the midinfrared between 5 and 11 microm with a temporal resolution of better than 400 fs. Multichannel detection with HgCdTe detector arrays consisting of ten elements in combination with a high repetition rate permits one to record weak absorbance changes with an accuracy of 0.1 mOD.
متن کاملGeneration of subpicosecond pulses from a continuous-wave mode-locked Nd:YAG laser using a two-stage optical compression technique.
By using a two-stage optical-fiber grating pair pulse-compression technique, 1.06-microm pulses as short as 0.7 psec have been obtained from an actively mode-locked cw Nd:YAG laser. This represents an overall pulse-compression ratio of 113.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics letters
دوره 18 22 شماره
صفحات -
تاریخ انتشار 1993