Continuous monitoring of mixed venous oxygen saturation in hemodynamically unstable patients.
نویسندگان
چکیده
A balloon-tipped catheter has recently become available which, when placed in the pulmonary artery, in addition to enabling the usual measurements of pulmonary arterial pressure, pulmonary capillary wedge pressure, and cardiac output by thermodilution, measures mixed venous oxygen saturation (SvO2) by spectrophotometry. Unlike the measurement of cardiac output by thermodilution, which is done intermittently, the continuous measurement of SvO2 is an effective method of monitoring hemodynamically unstable patients, since changes in cardiac output will immediately become apparent via a corresponding change in SvO2. This is of particular benefit in patients in whom knowledge of the immediate effects of therapy is important. It is also of value in assessing the time of onset of action and duration of action when a cardioactive drug is given to increase cardiac output. We suggest that monitoring SvO2 will provide an earlier indication of the effect of both diagnostic and therapeutic interventions and, therefore, will improve our management in such patients.
منابع مشابه
A continuous monitoring technique for management of acute pulmonary failure.
Continuous monitoring of mixed venous oxygen saturation (SvO2) and arterial oxygen saturation (SaO2) was used to guide cardiovascular and pulmonary physiologic manipulations in three patients. An index, termed the "shunt index" (SI), of venoarterial admixture (Qva/Qt) was calculated at the bedside. SI correlated significantly in each patient with Qva/Qt (p less than .01). In one of the patients...
متن کاملUsefulness of central venous oxygen saturation monitoring during bidirectional Glenn shunt.
A PediaSat™ oximetry catheter (PediaSat: Edwards Lifesciences Co., Ltd., Irvine, CA, U. S. A.), which facilitates continuous measurement of central venous oxygen saturation (ScvO2), may be useful for surgery for pediatric congenital heart disease. We used PediaSat during a bidirectional Glenn shunt. The patient was a 13-month-old boy. Under a diagnosis of left single ventricle (pulmonary atresi...
متن کاملContinuous monitoring of mixed venous oxygen saturation during aortic surgery.
The correlation between mixed venous oxygen saturation (SvO2) and hemodynamic measurements was studied in 13 patients undergoing descending thoracic aortic aneurysm resection (DTAAR). A significant correlation (p less than 0.05) was found between cardiac index (CI) and SvO2 after the induction of anesthesia and at the end of surgery. However, no significant correlation could be found between Sv...
متن کاملChallenges associated with central venous catheter placement and central venous oxygen saturation monitoring.
Patients with septic shock and respiratory failure often require hemodynamic monitoring in order to guide bedside management. This is particularly true of patients with dialysis-dependent chronic kidney disease, who may be less tolerant of large volume resuscitation than individuals with normal renal function. With the declining use of pulmonary artery catheters and the introduction of early go...
متن کاملValidity of Peripheral Capillary Oxygen Saturation and Normal Mixed Venous Oxygen Tension in Measurement of O2 Content
Background The change in venous oxygen saturation occurs earlier, and even its reduction is faster than arterial oxygen saturation. The aim of this study was to validate SvO2 and PvO2 for O2 content measurement in children hospitalized w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chest
دوره 86 5 شماره
صفحات -