Effect of small head tilt on ocular fundus image: Consideration of proper head positioning for ocular fundus scanning

نویسندگان

  • Shin Hae Park
  • Nam Yeo Kang
  • Jihyun Kim
  • Jiwon Baek
  • Seung Woo Hong
چکیده

Head tilt and resultant ocular cyclotorsion can influence the results of ophthalmologic examinations. Thus, proper head positioning during fundus scanning has been emphasized. However, there is no perfect method to control the head tilt and little is known about the effect of small head tilts. In this study, we investigated the effect of minimal head tilt on the ocular cyclotorsion which we cannot easily detect.Forty-seven participants without ophthalmologic or vestibular abnormalities were recruited as normal subjects. Their faces were positioned at the desired head tilt using a customized adjustable head tilter and facial and fundus photographs of both the left and right eyes were taken in the upright neutral position; as well as at rightward and leftward head tilts of 2°, 4°, and 6°. The actual head tilt was determined using the facial photographs by measuring the slope of a line that intersected the corneal reflexes of both eyes. Rotational changes in the fundus images were recorded and the correlation of these changes with the degree of head tilt was determined.The degree of head tilt was significantly correlated with rotational changes in the fundus images from both the right and left eyes (P < 0.001; right eye: R = 0.897, left eye: R = 0.899). The mean relative compensations for head tilt, mediated by the ocular counterrolling reflex, were 0.376 ± 0.255 in the right eye (range: -0.02 to 1.0), and 0.350 ± 0.263 in the left eye (range: -0.03 to 1.0), and exhibited a significant negative correlation with head tilt (P < 0.05). The mean relative compensation of the right eye did not differ significantly from that of the left eye (P = 0.380), but the value did vary widely among individuals and within individuals.Even very small head tilt was partially and variably compensated for, and caused significant rotation in the fundus image. We concluded that proper head positioning does not guarantee the minimal ocular cyclotorsion change of the eyes and image-adjusting technique would be a better solution for minimizing errors from ocular cyclotorsion changes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of cycloversions induced by head tilt on scanning laser polarimetry parameters.

OBJECTIVE To study the influence of cycloversions induced by head tilt on parameters of scanning laser polarimetry. METHODS Five left and five right eyes of 9 normal subjects were measured in seven different head tilt positions by one examiner using a scanning laser polarimeter (Nerve Fiber Analyzer, NFA II, LDT Inc., San Diego, Calif., USA). Images were acquired for the following head tilt p...

متن کامل

Does Decreased Static Ocular Counter Rolling Account for Bielschowsky Head Tilt Test in Unilateral Superior Oblique Palsy?

Purpose To understand the relationship of static ocular counter rolling (s-OCR) and clinical manifestations in acquired unilateral superior oblique palsy subjects during the Bielschowsky head tilt test. Methods Nineteen subjects that were diagnosed with acquired unilateral superior oblique palsy were included. Fundus photographs were obtained at different head tilt angles to evaluate static o...

متن کامل

Effect of dorzolamide and timolol on ocular blood flow in patients with primary open angle glaucoma and ocular hypertension.

BACKGROUND There is evidence that perfusion abnormalities of the optic nerve head are involved in the pathogenesis of glaucoma. There is therefore considerable interest in the effects of topical antiglaucoma drugs on ocular blood flow. A study was undertaken to compare the ocular haemodynamic effects of dorzolamide and timolol in patients with primary open angle glaucoma (POAG) or ocular hypert...

متن کامل

Two-dimensional segmentation of the retinal vascular network from optical coherence tomography.

The automatic segmentation of the retinal vascular network from ocular fundus images has been performed by several research groups. Although different approaches have been proposed for traditional imaging modalities, only a few have addressed this problem for optical coherence tomography (OCT). Furthermore, these approaches were focused on the optic nerve head region. Compared to color fundus p...

متن کامل

Infrared imaging of sub-retinal structures in the human ocular fundus

The interaction of infrared light with the human ocular fundus, particularly sub-retinal structures, was studied in vivo. Visible and infra-red wavelengths and a scanning laser ophthalmoscope were used to acquire digital images of the human fundus. The contrast and reflectance of selected retinal and sub-retinal features were computed for a series of wavelengths or modes of imaging. Near infrar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 95  شماره 

صفحات  -

تاریخ انتشار 2016