Effect of area x-ray beam equalization on image quality and dose in digital mammography.
نویسندگان
چکیده
In mammography, thick or dense breast regions persistently suffer from reduced contrast-to-noise ratio (CNR) because of degraded contrast from large scatter intensities and relatively high noise. Area x-ray beam equalization can improve image quality by increasing the x-ray exposure to under-penetrated regions without increasing the exposure to other breast regions. Optimal equalization parameters with respect to image quality and patient dose were determined through computer simulations and validated with experimental observations on a step phantom and an anthropomorphic breast phantom. Three parameters important in equalization digital mammography were considered: attenuator material (Z = 13-92), beam energy (22-34 kVp) and equalization level. A Mo/Mo digital mammography system was used for image acquisition. A prototype 16 x 16 piston driven equalization system was used for preparing patient-specific equalization masks. Simulation studies showed that a molybdenum attenuator and an equalization level of 20 were optimal for improving contrast, CNR and figure of merit (FOM = CNR2/dose). Experimental measurements using these parameters showed significant improvements in contrast, CNR and FOM. Moreover, equalized images of a breast phantom showed improved image quality. These results indicate that area beam equalization can improve image quality in digital mammography.
منابع مشابه
Calculation of Absorbed Glandular Dose using a FORTRAN Program Based on Monte Carlo X-ray Spectra in Mammography
Introduction: Average glandular dose calculation in mammography with Mo-Rh target-filter and dose calculation for different situations is accurate and fast. Material and Methods: In this research, first of all, x-ray spectra of a Mo target bombarded by a 28 keV electron beam with and without a Rh filter were calculated using the MCNP code. Then, we used the Sobol-Wu parameters to write a FORTRA...
متن کاملPrimary efforts to optimize image quality in chest direct digital radiography of pediatric patient (for the age group 0 to 1 and 1 to 5 years) with survey some effective parameters in image quality and patient dose
Introduction: This study, evaluate pediatric digital radiography. Due to the high rates of this test and the high sensitivity of children to ionizing radiation in comparison with adults, it is attempted to achieve near optimal conditions by reducing the dose and maintaining the image quality. The object of the study is to change the irradiation parameters such as kV and mA and ...
متن کاملCharacterization and Optimization of Silicon-strip Detectors for Mammography and Computed Tomography
The goal in medical x-ray imaging is to obtain the image quality required for a given detection task, while ensuring that the patient dose is kept as low as reasonably achievable. The two most common strategies for dose reduction are: optimizing incident x-ray beams and utilizing energy information of transmitted beams with new detector techniques (spectral imaging). In this thesis, dose optimi...
متن کاملExperimental investigation of the dose and image quality characteristics of a digital mammography imaging system.
Our purpose in this study was to investigate the image quality and absorbed dose characteristics of a digital mammography imaging system with a CsI scintillator, and to identify an optimal x-ray tube voltage for imaging simulated masses in an average size breast with 50% glandularity. Images were taken of an ACR accreditation phantom using a LORAD digital mammography system with a Mo target and...
متن کاملنتایج یک کُد فرترن برای محاسبه دوز غدهای در ماموگرافی با استفاده از پارامترهای Sobol-Wu
Background: Accurate computation of the radiation dose to the breast is essential to mammography. Various the thicknesses of breast, the composition of the breast tissue and other variables affect the optimal breast dose. Furthermore, the glandular fraction, which refers to the composition of the breasts, as partitioned between radiation-sensitive glandular tissue and the adipose tissue, also h...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 49 16 شماره
صفحات -
تاریخ انتشار 2004