Usefulness of central venous oxygen saturation monitoring during bidirectional Glenn shunt.

نویسندگان

  • Nami Kakuta
  • Shinji Kawahito
  • Naoji Mita
  • Noriko Kambe
  • Asuka Kasai
  • Narutomo Wakamatsu
  • Toshiko Katayama
  • Tomohiro Soga
  • Fumihiko Tada
  • Takashi Kitaichi
  • Tetsuya Kitagawa
  • Hiroshi Kitahata
چکیده

A PediaSat™ oximetry catheter (PediaSat: Edwards Lifesciences Co., Ltd., Irvine, CA, U. S. A.), which facilitates continuous measurement of central venous oxygen saturation (ScvO2), may be useful for surgery for pediatric congenital heart disease. We used PediaSat during a bidirectional Glenn shunt. The patient was a 13-month-old boy. Under a diagnosis of left single ventricle (pulmonary atresia, right ventricular hypoplasia, atrial septal defect) and residual left aortic arch/left superior vena cava, a modified right Blalock-Taussig shunt was performed. Cyanosis deteriorated, so a bidirectional Glenn shunt was scheduled. After anesthesia induction, a 4.5 Fr double-lumen (8 cm) PediaSat was inserted through the right internal jugular vein for continuous ScvO2 monitoring. Furthermore, the probe of a near-infrared, mixed blood oxygen saturation-measuring monitor was attached to the forehead for continuous monitoring of the regional brain tissue mixed blood oxygen saturation (rSO2) (INVOS™ 5100C, Covidien; Boulder, CO, U. S. A.). Blockage of the right pulmonary artery and right superior vena cava decreased the oxygen saturation, ScvO2, and rSO2, but increased the central venous pressure. Although changes in ScvO2 were parallel to those in rSO2, the former showed more marked changes. A combination of ScvO2 and rSO2 for monitoring during Glenn shunt may be safer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation of a novel noninvasive tissue oxygen saturation monitor to serum central venous oxygen saturation in pediatric patients with postoperative congenital cyanotic heart disease.

Using a novel noninvasive, visible-light optical diffusion oximeter (T-Stat VLS Tissue Oximeter; Spectros Corporation, Portola Valley, CA) to measure the tissue oxygen saturation (StO2) of the buccal mucosa, the correlation between StOz and central venous oxygen saturation (ScvO2) was examined in children with congenital cyanotic heart disease undergoing a cardiac surgical procedure. Paired StO...

متن کامل

Rapid development of a large systemic-to-pulmonary vein fistula after bidirectional Glenn shunt and successful closure with an Amplatzer duct occluder.

A7-month-old boy presented with significant cyanosis 17 days after bidirectional cavopulmonary shunting (Glenn procedure). He had previously undergone a Norwood operation at 7 days of age for a double-outlet right ventricle with hypoplastic left ventricle, hypoplastic aortic arch, and coarctation. Cardiac catheterization 10 days before the Glenn operation showed a pulmonary venous wedge pressur...

متن کامل

Placement of a modified cannula in the innominate vein for sufficient drainage during the bidirectional Glenn shunt procedure without cardiopulmonary bypass

During the bidirectional Glenn shunt procedure in small infants, the standard right-angle venous cannula is frequently placed in the innominate vein for establishing the temporary veno-atrial bypass without cardiopulmonary bypass, but it should be small enough to allow flow to pass around it from the internal jugular vein opposite to the side the cannula is directed. Small cannula may induce th...

متن کامل

Comparison of central-venous to mixed-venous oxygen saturation during changes in oxygen supply/demand.

Because central venous O2 saturation (superior vena cava, ScvO2) can be monitored with less patient risk than mixed venous O2 saturation (pulmonary artery, SvO2), we examined the correlations between SvO2 and ScvO2 over a broad range of cardiorespiratory conditions, including hypoxia, hemorrhage, and resuscitation in anesthetized dogs. The correlation coefficient (r) between SvO2 and ScvO2 in 1...

متن کامل

Analytical identification of ideal pulmonary-systemic flow balance in patients with bidirectional cavopulmonary shunt and univentricular circulation: oxygen delivery or tissue oxygenation?

BACKGROUND In the present study, we extended previous mathematical modeling work on patients with bidirectional cavopulmonary ("bidirectional Glenn") anastomosis to assess the potential utility of several descriptors of oxygen status. We set out to determine which of these descriptors best represents the overall tissue oxygenation. We also introduce a new descriptor, SO2min, defined as the lowe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of medical investigation : JMI

دوره 60 3-4  شماره 

صفحات  -

تاریخ انتشار 2013