Development of k0-INAA standardization method by neutron activation with Am-Be source.

نویسندگان

  • Huynh T Phuong
  • Mai V Nhon
  • Luu D H Oanh
چکیده

The k(0)-standardization method on the (241)Am-Be isotopic neutron source has been studied and developed. In this paper, the characteristics of the neutron spectrum in an isotropic neutron field of (241)Am-Be isotopic neutron sources was experimentally determined by dual monitor method using measured cadmium ratios of (197)Au(n, γ)(198)Au and (98)Mo(n, γ)(99)Mo(β(-))(99m)Tc reactions. Application of the k(0)-standardization method for the determination of elemental concentrations such as Al, Mn and Na in cement is carried out as well. The obtained results are in agreement with other analyses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing an Am-Be miniature neutron source

Background: Miniature neutron sources with high neutron flux have abundant applications in medicine, industry and researches. The most important general characteristic of miniature neutron sources is their diameter which is 3mm in average. In this research, we have surveyed and designed an Am-Be miniature neutron source fabrication. Materials and Methods: This investigation resulted in creation...

متن کامل

بررسی امکان استفاده از چشمه های نوترونی رادیوایزوتوپی در نوترون درمانی با بور

  Background : Performing successful BNCT experiments needs a suitable neutron source. Important factors of the neutron beam are flux and energy that are very important in the selection of neutron source. In most centers that use this method for treatment, reactor is a neutron source, which according to characteristics of the reactor appropriated neutrons are very high. High cost of constructin...

متن کامل

Determination of the flux of a neutron radioisotope source through gold activation method

Introduction: In recent years, the use of neutrons has increased in various fields such as medicine and industry. One of the important applications of neutrons is in medical research. Neutrons have greater linear energy transfer than gamma rays and are considered more dangerous radiation. Hence, the detection and determination of neutron dose is a very important and vital issu...

متن کامل

Characterization of Am-Be neutron source based PGNAA setup using aqueous solutions of Chlorine and Boron

Background: A 5 Ci 241Am-Be radio isotopic neutron source-based prompt gamma neutron activation analysis (PGNAA) setup was designed for estimation of minimum detectable concentration (MDC) of elements in aqueous solutions. Materials and Methods: Performance variables related to PGNAA setup (source to sample distance, sample to detector distance and volume of water) were optimized experimentally...

متن کامل

Quality assessment of INAA data for small-sized environmental reference samples.

Instrumental neutron activation analysis (INAA) was applied for the accurate and precise determination of minor and trace elements in small-sized aliquants (1 to 2 mg) of two certified reference materials (CRM), NIES No. 8 and NIST 1632c. Four laboratories used either comparative- or k0-INAA, or both, and repeated the analysis more than ten times for each CRM. Based on z-scores and zeta scores ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

دوره 70 3  شماره 

صفحات  -

تاریخ انتشار 2012