A Technique for Section Thickness Evaluation for Microphotometry and Image Analysis of Sectioned Nuclei
نویسندگان
چکیده
The exact knowledge of the section thickness is a requisite for making the necessary corrections on DNA measurements in tissue sections. Several methods have been proposed to evaluate section thickness, each of them with advantages and disadvantages depending on the type of specimen and equipment available. We herein report another method based on preparation of standard material whose optical density varies as a function of its thickness and is sectioned and measured alongside the tissue specimen. The standards consist of celloidin cylinders stained with the PAS reaction and embedded in paraffin. For prior characterization of the cylinders, sections of different thickness were obtained and mounted. The optical density of each section was measured by direct microphotometry or image analysis. The actual thickness of each section was evaluated following re-embedding of piled groups of sections in a paraffin block and transversal sectioning. The thickness was then measured with a micrometric eye-piece. Optical density and actual thickness of each section were plotted on a normogram curve. Once a given tissue is sectioned alongside with the reference cylinder, the actual thickness is determined by its optical density on the normogram curve.
منابع مشابه
P-27: Conservation Cloning of Esfahan Mouflon
Background: Among wide range of bio-conservational strategies envisaged, recent accomplishments in the field of somatic cell nuclear transfer (SCNT) holds considerable promise due to its unique potential to decelerate or prevent rapid loss of animal genetic resources, and even to revive extinct species. This study was undertaken to investigate whether domestic sheep in vitro matured and enuclea...
متن کاملنقش کلستاز در ایجاد آسیب بافتی مغز در ناحیۀ هیپوکامپ موش صحرایی نر نژاد ویستار
In cholestasis syndrome, the change of bile acids, salts, endotoxins and opioidsis is accompanied with hepaticencephalopathy and brain trauma; therefore, in this study, the histopathological changes of hippocampus after bile duct ligation were investigated. This study was performed on male Wistar rats. The rats were divided into three groups, namely the control, sham and cholestatic groups. Aft...
متن کاملAn Image Analysis-Based Methodology for Chromite Exploration through Opto-Geometric Parameters; a Case Study in Faryab Area, SE of Iran
Traditional methods of chromite exploration are mostly based on geophysical techniques and drilling operations. They are expensive and time-consuming. Furthermore, they suffer from several shortcomings such as lack of sufficient geophysical density contrast. In order to overcome these drawbacks, the current research work is carried out to introduce a novel, automatic and opto-geometric image an...
متن کاملMonte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography
Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...
متن کاملEvaluation of attenuation correction process in cardiac SPECT images
Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...
متن کامل