Mean aortic pressure is the geometric mean of systolic and diastolic aortic pressure in resting humans.
نویسندگان
چکیده
The aim of our study was twofold: 1) to establish a mathematical link between mean aortic pressure (MAP) and systolic (SAP) and diastolic aortic pressures (DAP) by testing the hypothesis that either the geometric mean or the harmonic mean of SAP and DAP were reliable MAP estimates; and 2) to critically evaluate three empirical formulas recently proposed to estimate MAP. High-fidelity pressures were recorded at rest at the aortic root level in controls (n = 31) and in subjects with various forms of cardiovascular diseases (n = 108). The time-averaged MAP and the pulse pressure (PP = SAP - DAP) were calculated. The MAP ranged from 66 to 160 mmHg [mean = 107.9 mmHg (SD 18.2)]. The geometric mean, i.e., the square root of the product of SAP and DAP, furnished a reliable estimate of MAP [mean bias = 0.3 mmHg (SD 2.7)]. The harmonic mean was inaccurate. The following MAP formulas were also tested: DAP + 0.412 PP (Meaney E, Alva F, Meaney A, Alva J, and Webel R. Heart 84: 64, 2000), DAP + 0.33 PP + 5 mmHg [Chemla D, Hébert JL, Aptecar E, Mazoit JX, Zamani K, Frank R, Fontaine G, Nitenberg A, and Lecarpentier Y. Clin Sci (Lond) 103: 7-13, 2002], and DAP + [0.33 + (heart rate x 0.0012)] PP (Razminia M, Trivedi A, Molnar J, Elbzour M, Guerrero M, Salem Y, Ahmed A, Khosla S, Lubell DL. Catheter Cardiovasc Interv 63: 419-425, 2004). They all provided accurate and precise estimates of MAP [mean bias = -0.2 (SD 2.9), -0.3 (SD 2.7), and 0.1 mmHg (SD 2.9), respectively]. The implications of the geometric mean pressure strictly pertained to the central (not peripheral) level. It was demonstrated that the fractional systolic (SAP/MAP) and diastolic (DAP/MAP) pressures were reciprocal estimates of aortic pulsatility and that the SAP times DAP product matched the total peripheral resistance times cardiac power product. In conclusion, although the previously described thumb-rules applied, the "geometric MAP" appears more valuable as it established a simple mathematical link between the steady and pulsatile component of aortic pressure.
منابع مشابه
Prospective evaluation of a method for estimating ascending aortic pressure from the radial artery pressure waveform.
Pressure wave reflection in the upper limb causes amplification of the arterial pulse so that radial systolic and pulse pressures are greater than in the ascending aorta. Wave transmission properties in the upper limbs (in contrast to the descending aorta and lower limbs) change little with age, disease, and drug therapy in adult humans. Such consistency has led to use of a generalized transfer...
متن کاملEmpirical estimates of mean aortic pressure: advantages, drawbacks and implications for pressure redundancy.
Mean arterial pressure (MAP) is estimated at the brachial artery level by adding a fraction of pulse pressure (form factor; =0.33) to diastolic pressure. We tested the hypothesis that a fixed form factor can also be used at the aortic root level. We recorded systolic aortic pressure (SAP) and diastolic aortic pressure (DAP), and we calculated aortic pulse pressure (PP) and the time-averaged MAP...
متن کاملHemodynamic effects of exercise in isolated valvular aortic stenosis.
Hemodynamic data, including simultaneously measured left ventricular and aortic pressures, were obtained from 20 patients with isolated valvular aortic stenosis at rest and during supine leg exercise. Changes in left ventricular end-diastolic pressure during exercise were not significantly related to the severity of aortic stenosis but were correlated with age; patients with abnormal left ventr...
متن کاملBALLOON ANGIOPLASTY IN NATIVE AORTIC COARCTATION: RESULT S IN SHIRAZ AND REVIEW OF ARTICLES
Balloon angioplasty for aortic coarctation was introduced in 1979 for the fust time.1 This procedure soon became the choice treatment for restenosis of operated coarctation,2-5 but remains controversial for native (unoperated) coarctation. However, it seems to be rapidly becoming the intervention of choice for relief of unoperated coarctation as well. In this study, we evaluate the outcome ...
متن کاملThe Effect of an 8-Week Concurrent Training on Plasma Endothelin_1 Level and Blood Pressure of Old Women
Background & Aims: Endothelin_1 secreted by endothelial cells has been identified as the strongest vascular constrictor. The aim of the present study was to investigate the role of concurrent training on plasma concentration of endothelin_1 and its relationship with blood pressure of old women. Methods: A total of 20 menopause women (Mean age: 67.47±5.92 years, mean body length: 152.92±7.52cm, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 99 6 شماره
صفحات -
تاریخ انتشار 2005