Revisiting corneal topography for the diagnosis of keratoconus: use of Rabinowitz’s KISA% index
نویسندگان
چکیده
BACKGROUND Numerous videokeratographic methods are used in the diagnosis of keratoconus. The purpose of this study was to compare the sensitivity and specificity of the KISA% index with the keratometry (K) value, inferior-superior (I-S) value, relative skewing of the steepest radial axes (SRAX), and keratometric astigmatism (AST) indices in 25 patients presenting with bilateral keratoconus. METHODS Twenty-five patients presenting with bilateral keratoconus were enrolled. Fifty eyes from 25 healthy individuals without corneal abnormalities were used as controls. The clinical diagnosis of keratoconus was made by observation of scissors reflex at retinoscopy and characteristic slit lamp findings. Corneal topographic analysis was performed in each eye to calculate the K value, I-S value, AST, and SRAX indices. RESULTS The keratoconus percentage index (KISA%) was significantly more sensitive and specific than the other indices examined. Furthermore, it was significantly better at predicting positive and negative results than the other indices included in the study. CONCLUSION The current research suggests that KISA% could be used to detect/diagnose keratoconus but further studies are required to confirm the specificity and sensitivity of KISA% for the detection of early-stage disease and keratoconus suspects.
منابع مشابه
KISA% index: a quantitative videokeratography algorithm embodying minimal topographic criteria for diagnosing keratoconus.
PURPOSE To formulate and test an algorithm using minimal topographic criteria for accurately diagnosing clinical keratoconus. SETTING Subspecialty cornea practice and Keratoconus Genetic Research Project. METHODS Both eyes of 86 keratoconic patients who had never worn contact lenses and 195 normal participants were studied with the TMS-1 videokeratoscope to evaluate the KISA% index, an algo...
متن کاملPrediction of Corneal Condition After Corneal Ring Implantation in Keratoconus Patients
Background: Keratoconus is a common complication among corneal defects. As a result of expeditious and extensive progress of medical science in recent decades, corneal ring implantation has turned into a successful surgical procedure to correct the vision of Keratoconus patients; however, selecting the right patient is essential in the success of the operation. The prediction of corneal conditi...
متن کاملCorneal Ectasis among Wrestlers: Report of Two Cases
Report keratoconus in two patients with a long history of wrestling without any risk factor for corneal ectasia and reviewing the possible pathogenesis. To confirm suspicion of keratoconus, corneal topography was performed using scanning slit topography system and Orbscan. In two wrestlers with the complaint of visual loss in their eyes and IOP raising, corneal topography was performed and de...
متن کاملKeratoconus Screening in Primary Eye Care – A General Overview
K eratoconus early detection (screening) and diagnosis requires an in-deep corneal analysis with different techniques; slip lamp assessment, corneal topography and corneal tomography are the most commonly accepted to detect clinical signs and assess anterior and posterior corneal surface and global corneal pachymetry. However, keratoconus early detection and definitive diagnosis are two differe...
متن کاملFusion of Different Corneal Parameters to Improve the Diagnosis of Keratoconus
Purpose: To diagnose keratoconus from healthy eyes, as well as suspected keratoconus. Methods: Certain parameters were extracted from Casia, Corvis, and Pentacam HR devices for 3 groups of healthy, with keratoconus, and suspected keratoconus. This study was performed on 340 eyes with keratoconus, 310 normal eyes, and 350 suspected keratoconus. The processing method involved the fusion of featur...