BACKGROUND Sensitive diagnostic tools are required for an accurate assessment of prevalence and intensity of helminth infections in areas undergoing regular deworming, and for monitoring anthelmintic drug efficacy. We compared the diagnostic accuracy of the Kato-Katz and FLOTAC techniques in the frame of a drug efficacy trial. METHODOLOGY/PRINCIPAL FINDINGS Stool samples from 343 Zanzibari children were subjected to duplicate Kato-Katz thick smears and the FLOTAC basic technique in a baseline screening in early 2009. The FLOTAC showed a higher sensitivity than the Kato-Katz method for the diagnosis of Trichuris trichiura (95% vs. 88%, p = 0.012) and Ascaris lumbricoides (88% vs. 68%, p = 0.098), but a lower sensitivity for hookworm diagnosis (54% vs. 81%, p = 0.006). Considering the combined results from both methods as 'gold' standard, the prevalences of T. trichiura, hookworm and A. lumbricoides were 71% (95% confidence interval (CI): 66-75%), 22% (95% CI: 17-26%) and 12% (95% CI: 8-15%), respectively. At follow-up, 3-5 weeks after 174 among the 269 re-examined children were administered anthelmintic drugs, we observed cure rates (CRs) against A. lumbricoides, hookworm and T. trichiura of 91% (95% CI: 80-100%), 61% (95% CI: 48-75%) and 41% (95% CI: 34-49%), respectively, when using the Kato-Katz method. FLOTAC revealed lower CRs against A. lumbricoides (83%, 95% CI: 67-98%) and T. trichiura (36%, 95% CI: 29-43%), but a higher CR against hookworm (69%, 95% CI: 57-82%). These differences, however, lacked statistical significance. Considerable differences were observed in the geometric mean fecal egg counts between the two methods with lower egg reduction rates (ERRs) determined by FLOTAC. CONCLUSION/SIGNIFICANCE Our results suggest that the FLOTAC technique, following further optimization, might become a viable alternative to the Kato-Katz method for anthelmintic drug efficacy studies and for monitoring and evaluation of deworming programs. The lower CRs and ERRs determined by FLOTAC warrant consideration and could strategically impact future helminth control programs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic Accuracy of Kato–Katz, FLOTAC, Baermann, and PCR Methods for the Detection of Light-Intensity Hookworm and Strongyloides stercoralis Infections in Tanzania

Sensitive diagnostic tools are crucial for an accurate assessment of helminth infections in low-endemicity areas. We examined stool samples from Tanzanian individuals and compared the diagnostic accuracy of a real-time polymerase chain reaction (PCR) with the FLOTAC technique and the Kato-Katz method for hookworm and the Baermann method for Strongyloides stercoralis detection. Only FLOTAC had a...

متن کامل

Diagnostic Accuracy and Cost-Effectiveness of Alternative Methods for Detection of Soil-Transmitted Helminths in a Post-Treatment Setting in Western Kenya

OBJECTIVES This study evaluates the diagnostic accuracy and cost-effectiveness of the Kato-Katz and Mini-FLOTAC methods for detection of soil-transmitted helminths (STH) in a post-treatment setting in western Kenya. A cost analysis also explores the cost implications of collecting samples during school surveys when compared to household surveys. METHODS Stool samples were collected from child...

متن کامل

Comparing Diagnostic Accuracy of Kato-Katz, Koga Agar Plate, Ether-Concentration, and FLOTAC for Schistosoma mansoni and Soil-Transmitted Helminths

BACKGROUND Infections with schistosomes and soil-transmitted helminths exert a considerable yet underappreciated economic and public health burden on afflicted populations. Accurate diagnosis is crucial for patient management, drug efficacy evaluations, and monitoring of large-scale community-based control programs. METHODS/PRINCIPAL FINDINGS The diagnostic accuracy of four copromicroscopic t...

متن کامل

Sensitivity of diagnostic tests for human soil-transmitted helminth infections: a meta-analysis in the absence of a true gold standard

Reliable, sensitive and practical diagnostic tests are an essential tool in disease control programmes for mapping, impact evaluation and surveillance. To provide a robust global assessment of the relative performance of available diagnostic tools for the detection of soil-transmitted helminths, we conducted a meta-analysis comparing the sensitivities and the quantitative performance of the mos...

متن کامل

A single FLOTAC is more sensitive than triplicate Kato-Katz for the diagnosis of low-intensity soil-transmitted helminth infections.

Accurate diagnostic tools are pivotal for patient management and surveillance of helminth control programmes, particularly in the current era of preventive chemotherapy. Three consecutive stool samples were obtained from 279 schoolchildren from Zanzibar, an island where anthelminthic drugs have been administered on a large scale for more than a decade. All stool samples were examined with the K...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2011