Measurement of polyethylene glycol 400 in urine by direct-injection high-performance liquid chromatography.

نویسندگان

  • G O Young
  • D Ruttenberg
  • J P Wright
چکیده

We describe a new "high-performance" liquid chromatographic (HPLC) method for estimating polyethylene glycol 400 (PEG 400) in urine. Direct injection of diluted urine samples onto the column eliminates the necessity for lengthy preparative steps, resulting in considerable saving of both time and chemicals. High analytical recoveries (94-102%) and a rapid rate of analysis are achieved. Results vary linearly with concentrations from 0.2 to 1.6 g/L and the six major components can be individually quantified precisely at all concentrations in this range. This method shows better sample recovery, sensitivity, and reproducibility than does a previously described method. The increased sensitivity should allow the use of lower oral doses of polyethylene glycol 400 in future studies of intestinal permeability.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HPLC-electrospray mass spectrometry for the analysis of temoporfin-poly(ethylene glycol) conjugates.

The photodynamic therapeutic agent temoporfin, 5,10,15,20-tetra(m-hydroxyphenyl)chlorin (m-THPC) conjugated with poly(ethylene glycol) 2000 (PEG), has been analysed by high performance liquid chromatography (HPLC), linked to electrospray ionisation mass spectrometry (ESI-MS). Sufficient separation of m-THPC-PEG 2000 oligomers was achieved, enabling determination of molecular mass. The use of ES...

متن کامل

Analysis of acetoin and diacetyl in bacterial culture supernatants by gas-liquid chromatography.

The acetoin and diacetyl contents of culture supernatants of Voges-Proskauer-positive "viridans" streptotocci, Klebsiella pneumoniae and Staphylococcus aureus, were determined by a gas liquid chromatographic procedure, in which supernatants were extracted with diethyl ether and diacetyl was measured on columns of 10% (wt/wt) polyethylene glycol 400 (PEG 400) at 73 C. Acetoin was converted to di...

متن کامل

Degradation Kinetics of Benzyl Nicotinate in Aqueous Solution

The degradation of benzyl nicotinate in aqueous solution over a pH range of 2.0-10.0 at 50+/-0.2 degrees was studied. The degradation was determined by high performance liquid chromatography. The degradation was observed to follow apparent first-order rate kinetics and the rate constant for the decomposition at 25 degrees was estimated by extrapolation. The reaction was shown to be hydroxide io...

متن کامل

Human plasma derived drugs separation by fractionation of plasma with polyethylene glycol

Background: There are varieties of purification techniques for separation of human plasma proteins such as salting out, ion exchange chromatography, and ethanol fractionation. There are limitations for each method, for example in salting out method, the salt has to be removed in an additional step. Ion exchange chromatography is difficult for scaling up, and plasma fractionation is a time consu...

متن کامل

One-pot and efficient synthesis of triazolo[1,2-a]indazole-triones catalyzed by poly(ethylene glycol) based magnetic dicationic ionic liquid

An atom-efficient, eco-friendly, solvent-free, high yielding, multicomponent green strategy to synthesize triazolo[1,2-a]indazole-triones derivatives by the one-pot condensation of aldehyde, dimedone, and phenyl urazole is presented. A series of different substituted aromatic aldehydes including either electron-withdrawing or electron-donating groups used in this reaction participated well and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 36 10  شماره 

صفحات  -

تاریخ انتشار 1990