NQR Characteristics of an RDX Plastic Explosives Simulant
نویسندگان
چکیده
For reliable detection of explosives, a combination of methods integrated within a single measurement platform may increase detection performance. However, the efficient field testing of such measurement platforms requires the use of inexplosive simulants that are detectable by a wide range of methods. Physical parameters such as simulant density, elemental composition and crystalline structure must closely match those of the target explosive. The highly discriminating bulk detection characteristics of nuclear quadrupole resonance (NQR) especially constrain simulant design. This paper describes the development of an inexplosive RDX simulant suited to a wide range of measurement methods, including NQR. Measurements are presented that confirm an RDX NQR response from the simulant. The potential use of the simulant for field testing a prototype handheld NQR-based RDX detector is analyzed. Only modest changes in prototype operation during field testing would be required to account for the use of simulant rather than real explosive.
منابع مشابه
Investigation of Wavelet-based Enhancements to Nuclear Quadrupole Resonance Explosives Detectors*
Nuclear Quadrupole Resonance (NQR) is effective for the detection and identification of certain types of explosives such as RDX, PETN and TNT. In explosive detection, the NQR response of certain 14N nuclei present in the crystalline material is probed. The 14N nuclei possess a nuclear quadrupole moment which in the presence of an electric field gradient produces an energy level splitting which ...
متن کاملTrace Detection of RDX, HMX and PETN Explosives Using a Fluorescence Spot Sensor
1,3,5-trinitroperhydro-1,3,5-triazine (RDX), octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), and pentaerythritol tetranitrate (PETN), the major components in plastic explosives, pose a significant threat to public safety. A quick, sensitive, and low-cost detection method for these non-volatile explosives is eagerly demanded. Here we present a fluo-spot approach, which can be employed fo...
متن کاملElectrostatic Hazards Assessment of Nitramine Explosives: Resistivity, Charge Accumulation and Discharge Sensitivity
The electrostatic hazards of nitramine explosives (RDX, HMX) were assessed in this paper. The resistivities of different particle-size RDX and HMX were tested by a device designed and manufactured according to the standard ISO/ IEC 80079-20-2:2016. This work shows that the resistivities of uncompacted RDX and HMX increase as the particle size decreases. Charging characteristics test experiments...
متن کاملOptimized thermal desorption for improved sensitivity in trace explosives detection by ion mobility spectrometry.
In this work we evaluate the influence of thermal desorber temperature on the analytical response of a swipe-based thermal desorption ion mobility spectrometer (IMS) for detection of trace explosives. IMS response for several common high explosives ranging from 0.1 ng to 100 ng was measured over a thermal desorber temperature range from 60 °C to 280 °C. Most of the explosives examined demonstra...
متن کاملAtomistic studies of RDX and FOX-7 -Based Plastic-Bonded explosives: molecular dynamics simulation
Molecular dynamics simulations were carried out to study the effects of interface interactions between a crystalline structure and a plastic bonded explosive (PBX) system. In this work, the hydroxyl-terminated polybutadiene (HTPB) represents the polymer, isophorone diisocyanate (IPDI) is the diisocyanate and dioctyl adipate (DOA) is the plasticizer. Two different crystal high explosives compone...
متن کامل