Comparison between the 133Xe clearance method and the microsphere technique in cerebral blood flow determinations in the dog.

نویسندگان

  • F C Fan
  • R Y Chen
  • G B Schuessler
  • S Chien
چکیده

Copyright © 1979 American Heart Association. All rights reserved. Print ISSN: 0009-7330. Online ISSN: TX 72514 Circulation Research is published by the American Heart Association. 7272 Greenville Avenue, Dallas, 1979;44;653-659 Circ. Res. FC Fan, RY Chen, GB Schuessler and S Chien in cerebral blood flow determinations in the dog Comparison between the 133Xe clearance method and the microsphere technique http://circres.ahajournals.org located on the World Wide Web at: The online version of this article, along with updated information and services, is

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison between hydrogen clearance and microsphere technique for rCBF measurement.

Regional cerebral blood flow was measured repeatedly in anesthetized and immobilized cats under various experimental conditions by recording the clearance of inhaled hydrogen with inserted platinum electrodes and by recording the distribution of 15 mu microspheres labeled with 3 different radioisotopes. The values for both methods in normal cortical tissue were comparable (75.7 +/- 23.5 ml/100 ...

متن کامل

Muscle blood flow during intermittent exercise: comparison of the microdialysis ethanol technique and 133Xe clearance.

1. Local skeletal muscle blood flow was monitored using the microdialysis ethanol technique and 133Xe clearance during intermittent isometric contractions (5 s on/10 s off) of the thigh at 0-60% of the maximal voluntary isometric contraction force. 2. A linear increase in blood flow over a 25-fold range was detected using both 133Xe clearance and the microdialysis ethanol technique. 3. The medi...

متن کامل

Stochastic analysis of 133xe clearance for determining regional cerebral blood flow in a primate model.

A technique for stochastic analysis of 133Xe washout using a computer-assisted Anger camera is described. The technique produces functional maps of both regional cerebral blood flow (rCBF) and error in rCBF. The calculational limitations of the technique are discussed and an experimental estimate made of the physical limitations associated with the low energy photon emitted by 133Xe. The method...

متن کامل

Spectrum subtraction technique for minimizing extracranial influence on cerebral blood flow measurements by 133xenon inhalation.

Estimates of regional cerebral blood flow (rCBF) by the 133Xe inhalation method are influenced by isotope contamination from slow clearing extracerebral tissues. Subtraction of x-ray (31 kev) from gamma-ray counts (81 kev) has been suggested as a means of yielding clearance curves that are relatively free of such contamination. In the present study, rCBF measurements based on the total 133Xe sp...

متن کامل

Comparison of thermal clearance measurement of regional cerebral blood flow with radiolabelled microspheres.

A thermal clearance technique for measuring cerebral blood flow is described and compared with the radiolabelled microsphere technique. The thermal technique involves measurement of the rewarming curve generated after bolus infusion of 4-5 ml of ice-cold saline into the common carotid artery with a subdural thermistor placed on the parietal cortex. Evaluation of the biexponential decay curves o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 44 5  شماره 

صفحات  -

تاریخ انتشار 1979