Impact of Statin Treatment on Strut Coverage after Drug-Eluting Stent Implantation

نویسندگان

  • Yongsung Suh
  • Byeong-Keuk Kim
  • Dong-Ho Shin
  • Jung-Sun Kim
  • Young-Guk Ko
  • Donghoon Choi
  • Yangsoo Jang
  • Myeong-Ki Hong
چکیده

PURPOSE To evaluate the effect of statin treatment on strut coverage after drug-eluting stent (DES) implantation. MATERIALS AND METHODS In this study, 60 patients were randomly assigned to undergo sirolimus-eluting stent (SES) or biolimus-eluting stent (BES) implantation, after which patients were randomly treated with pitavastatin 2 mg or pravastatin 20 mg for 6 months. The degree of strut coverage was assessed by 6-month follow-up optical coherence tomography, which was performed in 52 DES-implanted patients. RESULTS The percentages of uncovered struts were 19.4±14.7% in pitavastatin-treated patients (n=25) and 19.1±15.2% in pravastatin-treated patients (n=27; p=0.927). A lower percentage of uncovered struts was significantly correlated with a lower follow-up low-density lipoprotein (LDL) cholesterol level (r=0.486; p=0.009) and a greater decline of the LDL cholesterol level (r=-0.456; p=0.015) in SES-implanted patients, but not in BES-implanted patients. In SES-implanted patients, the percentage of uncovered struts was significantly lower among those with LDL cholesterol levels of less than 70 mg/dL after 6 months of follow-up (p=0.025), but no significant difference in this variable according to the follow-up LDL cholesterol level was noted among BES-implanted patients (p=0.971). CONCLUSION Lower follow-up LDL cholesterol levels, especially those less than 70 mg/dL, might have a protective effect against delayed strut coverage after DES implantation. This vascular healing effect of lower LDL cholesterol levels could differ according to the DES type.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Incomplete stent apposition causes high shear flow disturbances and delay in neointimal coverage as a function of strut to wall detachment distance: implications for the management of incomplete stent apposition.

BACKGROUND Lack of re-endothelialization and neointimal coverage on stent struts has been put forward as the main underlying mechanism leading to late stent thrombosis. Incomplete stent apposition (ISA) has been observed frequently in patients with very late stent thrombosis after drug eluting stent implantation, suggesting a role of ISA in the pathogenesis of this adverse event. The aim of thi...

متن کامل

Effect of High-Dose Statin Therapy on Drug-Eluting Stent Strut Coverage.

OBJECTIVE The influence of high-dose statin therapy on the serial stent healing process has not been fully investigated. Using optical coherence tomography, the effect of high-dose statin therapy on stent strut coverage was evaluated in drug-eluting stent-treated patients. APPROACH AND RESULTS Sixty patients were randomly assigned to 2 groups according to the statin dose (atorvastatin 40 mg a...

متن کامل

Randomized comparison of stent strut coverage following angiography- or optical coherence tomography-guided percutaneous coronary intervention.

INTRODUCTION AND OBJECTIVES The clinical benefits of optical coherence tomography-guided percutaneous coronary intervention are unclear. Therefore, in this study we sought to evaluate the impact of optical coherence tomography guidance on stent strut coverage following drug-eluting stent implantation. METHODS A total of 101 patients in 105 lesions were randomly assigned to receive percutaneou...

متن کامل

The relationship between re-endothelialization and endothelial function after DES implantation: Comparison between paclitaxcel eluting stent and zotarolims eluting stent

BACKGROUND Several studies have reported re-endothelialization and endothelial function after drug-eluting stent (DES) implantation; however, the relationship between re-endothelialization and endothelial function after DES implantation has not been investigated yet. METHODS A total of 14 patients underwent evaluation of re-endothelialization by optical coherence tomography (OCT) and endothel...

متن کامل

The relationship between post-stent strut apposition and follow-up strut coverage assessed by a contour plot optical coherence tomography analysis.

OBJECTIVES This study sought to evaluate the relationship between post-stent strut apposition and follow-up strut coverage using contour plot optical coherence tomographic analysis. BACKGROUND Tracking the fate of interested regions of struts at different time points has not been investigated. METHODS Post-intervention and 6-month follow-up optical coherence tomographic evaluations were per...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 56  شماره 

صفحات  -

تاریخ انتشار 2015