Analysis of indoor climate and occupants’ behaviour in traditional Scottish dwellings

نویسنده

  • Amar Bennadji
چکیده

Due to the relevance of the internal boundary conditions and the lack of specific data for the Scottish context, an exploration of the internal environment of traditional dwellings is needed. In this study the indoor climate of 24 properties with different levels of insulation and air-tightness was analysed using a combination of quantitative and qualitative data. Temperature and relative humidity were recorded at 15 minutes intervals in two rooms per property. The analysis was complemented with semi-structured interviews with the occupants. Based on temperature and relative humidity, the moisture loads were calculated. Results in noninsulated properties showed indoor temperatures lower than the minimum level of thermal comfort, especially in winter, and high values of relative humidity during the warm season. The humidity levels in upgraded buildings are consistently lower despite the greater variability found in the internal temperatures. © 2015 The Authors. Published by Elsevier Ltd. Peer-review under responsibility of the CENTRO CONGRESSI INTERNAZIONALE SRL.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Indoor radon measurements in residential dwellings in Qom, Iran

Background: Inhalation of radon and its short-lived decay products is one of the ‎most significant sources of exposure to natural radiation. Radon is the second cause ‎of lung cancer in the populations. The present study was carried out under the projects of ‎national radon, with the aim of determining the concentration of indoor in the city of Qom ‎located in the central se...

متن کامل

Thermal performance study and evaluation of comfort temperatures in vernacular buildings of North-East India

Solar passive techniques are being used in vernacular buildings throughout the world. Researchers have done extensive study on thermal performance of vernacular buildings in the different parts of the world. Vernacular architecture of North-Eastern India represents the principle of climate-responsive architecture, which still lacks experimental validation and quantitative analysis. Thermal comf...

متن کامل

Indoor Radon Measurement in Dwellings of Khorramabad City, Iran

Introduction: Exposure to indoor radon increases the risk of lung cancer. This study examined the level of indoor radon in dwellings of Khorramabad city, by using passive alpha-track detector (CR-39) during winter of 2016. Materials and Methods: In the present study, we detected the concentration of indoor radon in 56 dwellings. A passive sampling instrument (alpha-track detector with CR-39 pol...

متن کامل

Health Risk Assessment of Inhalation Exposure to Formaldehyde and Benzene in Newly Remodeled Buildings, Beijing

OBJECTIVE To assess health risks associated with inhalation exposure to formaldehyde and benzene mainly emitted from building and decoration materials in newly remodeled indoor spaces in Beijing. METHODS We tested the formaldehyde and benzene concentrations in indoor air of 410 dwellings and 451 offices remodeled within the past year, in which the occupants had health concerns about indoor ai...

متن کامل

Radon level in dwellings basement of Yazd-Iran

Background: Indoor radon gas (222Rn) has been recognized as one of the health hazards for human. Air radon comes mainly from basement soil and construction materials. Saghand region with rich uranium mines lies 180 km from Yazd, so the indoor radon concentration can be high. Yazd, with population of about 457000, is the biggest city near Saghand, thus, indoor gamma background radiation of Yazd ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016