BACKGROUND A diastolic coronary flow murmur has been reported for patients with coronary stenoses, yet is rarely appreciated during routine auscultation. We hypothesized that an ultrasonic Doppler method can detect the epicardial vibrations associated with this murmur. Ultrasonic Doppler vibrometry is a pulsed wave echocardiography phase demodulation technique designed for detecting vibrations. We correlated the vibration characteristics measured using vibrometry with the angiographic severity of coronary artery stenosis. METHODS In a prospective pilot study, 49 patients were recruited for an ultrasound examination before coronary arteriography. An ultrasound instrument was customized to acquire the raw pulsed wave Doppler echocardiographic data from a range gate placed on the left ventricular myocardium near the path of the epicardial coronary arteries. RESULTS Patients with angiographically minor stenosis (tightest stenosis < 50% by quantitative coronary angiography, N = 25) had lower diastolic vibration energy (computed as the median spectral energy of myocardial wall velocity in the 100 approximately 1000-Hz frequency band normalized by a baseline diastolic value) compared with patients with moderate or severe stenosis (any stenosis > 50%, N = 24) (P < .001, area under the receiver operating characteristics curve = 0.84). The vibration energy increased with increasing stenosis severity for less severe narrowing (<70%) but decreased for severe narrowing (>70%) (R(2) = 0.21, P < .0002). CONCLUSIONS Preliminary evidence indicates that diastolic left ventricular wall vibrations measured using ultrasonic Doppler vibrometry are related to the severity of coronary artery stenoses. With further refinement and validation, this noninvasive and low-cost method could lead to an early screening and monitoring test for coronary artery stenosis.
منابع مشابه
Non-invasive estimation of cardiac wall stress by using tissue doppler-echocardiography ultrasound images: People with coronary artery stenosis
In this study, a method for non-invasive estimation of stress on the heart wall in the diastole phase is presented using ultrasound echocardiography and tissue Doppler imaging. The aim of this study was to evaluate the stress on the heart wall as a pre-diagnosis to identify people with coronary artery stenosis. 29 patients with stenosis of more than 70%, 30 patients with stenosis of 50 to 7...
متن کامل2150 Correlation of Pharmacological 99 mTcwSestamibi Myocardial Perfusion Imaging With Poststenotic Coronary Flow Reserve in Patients With Angiographically Intermediate Coronary Artery Stenoses
Backgrnd The physiological assessment of angiographically intermediate-severity stenoses remains problematic. Functional measurements of poststenotic intracoronary Doppler coronary flow reserve can be performed in humans but have not been correlated with hyperemic myocardial perfusion imaging or angiographic data in this patient population. Method and Resus Thirty-three patients undergoing diag...
متن کاملCorrelation of Pharmacological 99 mTcwSestamibi Myocardial Perfusion Imaging With Poststenotic Coronary Flow Reserve in Patients With Angiographically Intermediate Coronary Artery Stenoses
Backgrnd The physiological assessment of angiographically intermediate-severity stenoses remains problematic. Functional measurements of poststenotic intracoronary Doppler coronary flow reserve can be performed in humans but have not been correlated with hyperemic myocardial perfusion imaging or angiographic data in this patient population. Method and Resus Thirty-three patients undergoing diag...
متن کاملCorrelation of Pharmacological 99 mTcwSestamibi Myocardial Perfusion Imaging With Poststenotic Coronary Flow Reserve in Patients With Angiographically Intermediate Coronary Artery
Backgrnd The physiological assessment of angiographically intermediate-severity stenoses remains problematic. Functional measurements of poststenotic intracoronary Doppler coronary flow reserve can be performed in humans but have not been correlated with hyperemic myocardial perfusion imaging or angiographic data in this patient population. Method and Resus Thirty-three patients undergoing diag...
متن کاملIdentification of coronary artery stenoses and poststenotic blood flow patterns using a miniature high-frequency epicardial transducer.
BACKGROUND Intraoperative epicardial coronary Doppler ultrasound has the potential to provide anatomic and functional information. This technique has been hindered by the large size of standard transducers, but a miniature transducer is available that may fulfill the potential of coronary ultrasound. METHODS AND RESULTS Twenty consecutive patients who were undergoing coronary artery bypass gr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
دوره 20 12 شماره
صفحات -
تاریخ انتشار 2007