Comment on 'Proton beam monitor chamber calibration'.

نویسندگان

  • Hugo Palmans
  • Stanislav M Vatnitsky
چکیده

We comment on a recent article (Gomà et al 2014 Phys. Med. Biol. 59 4961-71) which compares different routes of reference dosimetry for the energy dependent beam monitor calibration in scanned proton beams. In this article, a 3% discrepancy is reported between a Faraday cup and a plane-parallel ionization chamber in the experimental determination of the number of protons per monitor unit. It is further claimed that similar discrepancies between calorimetry and ionization chamber based dosimetry indicate that [Formula: see text]-values tabulated for proton beams in IAEA TRS-398 might be overestimated. In this commentary we show, however, that this supporting argument misrepresents the evidence in the literature and that the results presented, together with published data, rather confirm that there exist unresolved problems with Faraday cup dosimetry. We also show that the comparison in terms of the number of protons gives a biased view on the uncertainty estimates for both detectors while the quantity of interest is absorbed dose to water or dose-area-product to water, even if a beam monitor is calibrated in terms of the number of protons. Gomà et al (2014 Phys. Med. Biol. 59 4961-71) also report on the discrepancy between cylindrical and plane-parallel ionization chambers and confirm experimentally that in the presence of a depth dose gradient, theoretical values of the effective point of measurement, or alternatively a gradient correction factor, account for the discrepancy. We believe this does not point to an error or shortcoming of IAEA TRS-398, which prescribes taking the centre of cylindrical ionization chambers as reference point, since it recommends reference dosimetry to be performed in the absence of a depth dose gradient. But these observations reveal that important aspects of beam monitor calibration in scanned proton beams are not addressed in IAEA TRS-398 given that those types of beams were not widely implemented at the time of its publication.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetry of pulsed clinical proton beams by a small ionization chamber.

Response of a micro volume (0.01 ml) ionization chamber has been studied with pulsed proton beams which are used for clinical purposes and has been compared with those of some JARP ionization chambers (0.6 ml). All chambers used had been calibrated by standard 60Co beams at the Electrotechnical Laboratory (ETL) and exposure calibration factors, Nx, were obtained on advance. Two methods are used...

متن کامل

A Gas Monitor Chamber Calibration Program for the ATLAS Muon Spectrometer Precision Chambers

The ATLAS Muon Spectrometer is designed to measure the momentum of muons with a resolution of dp/p = 3% and 10 % at beam energies of 100 GeV and 1 TeV respectively. To do this, the spectrometer employs 355,000 Monitored Drift Tubes (MDTs) in 1200 Chambers. Calibration (RT) functions convert drift time measurements into tube-centered impact parameters for track segment reconstruction. RT functio...

متن کامل

Radiographic film dosimetry of proton beams for depth‐dose constancy check and beam profile measurement

Radiographic film dosimetry suffers from its energy dependence in proton dosimetry. This study sought to develop a method of measuring proton beams by the film and to evaluate film response to proton beams for the constancy check of depth dose (DD). It also evaluated the film for profile measurements. To achieve this goal, from DDs measured by film and ion chamber (IC), calibration factors (rat...

متن کامل

Evaluation of Gafchromic® EBT3 films characteristics in therapy photon, electron and proton beams.

PURPOSE To evaluate the uncertainties and characteristics of radiochromic film-based dosimetry system using the EBT3 model Gafchromic(®) film in therapy photon, electron and proton beams. MATERIAL AND METHODS EBT3 films were read using an EPSON Expression 10000XL/PRO scanner. They were irradiated in five beams, an Elekta SL25 6 MV and 18 MV photon beam, an IBA 100 MeV 5 × 5 cm(2) proton beam ...

متن کامل

European Organization for Nuclear Research Cern Sl Division

See the introduction in next page. EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CERN SL DIVISION 2 Energy Spectrum Measurement of the Multipacting Electrons in the SPS. Analysis of the Possible Utilisation of the BGIP Monitor ------------------------------------------------------------------------------------------------------------------------Mauro Pivi CERN – LHC Division – VAC Group Alessandro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 61 17  شماره 

صفحات  -

تاریخ انتشار 2016