Application of Intra-Aortic Balloon Pump in Resection and Anastomosis of Trachea

نویسندگان

  • Zargham Hossein Ahmadi
  • Amir Ali Rahnemai-Azar
  • Mohammad Behgam Shadmehr
  • Tahereh Parsa
  • Neda Behzadnia
  • Zahra Ansari Aval
  • Bahareh Mokri
  • Hamideh Gholamhoseini
چکیده

The intra-aortic balloon pump (IABP) is a mechanical device used to assist cardiac circulatory function in patients suffering from cardiogenic shock, congestive heart failure, refractory angina and complications of myocardial infarction. While using IABP in cardiac surgery is well established, there are few studies on the utility of IABP support in high-risk cardiac patients undergoing non-cardiac surgery. Major non-cardiac surgeries are associated with high rates of cardiac complications in patients with advanced coronary disease. Recent case studies have reported favorable outcomes with the use of IABP support in non-cardiac surgery in patients with severe cardiac compromise. Using IABP may reduce cardiac complications by providing hemodynamic stability. Here, we present five cases of IABP use in high-risk cardiac patients undergoing resection and anastomosis of the trachea. IABP was inserted prior to induction of anesthesia in four of the cases, while IABP insertion was withheld in one case. In the four cases where IABP support was utilized, the IABP was removed between 6-48 hours postoperatively with no complications. The patient who did not undergo IABP insertion died on the 8th postoperative day due to uncontrollable pulmonary edema and progressive myocardial infarction. We also review the literature and discuss the role of IABP use in non-cardiac surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery

Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods:  In thi...

متن کامل

Evaluation of Factors Influencing Liver Function Test in On-Pump Coronary Artery Bypass Graft Surgery

Background: Liver dysfunction during on-pump coronary artery bypass graft surgery (CABG) is a rare complication but is associated with significant morbidity and mortality. The ability to identify high-risk patients may be helpful in planning appropriate management strategies. We aimed to evaluate the factors influencing liver function tests during on-pump CABG.Methods: In 146 patients scheduled...

متن کامل

A novel coronary active perfusion system using a conventional intra-aortic balloon pump for off-pump coronary artery bypass grafting.

OBJECTIVE It is important for coronary active perfusion systems to avoid myocardial ischemia during off-pump coronary artery bypass grafting. We have developed a new concept for a perfusion system to pump blood based on changes in helium gas volume. This system uses a conventional intra-aortic balloon pump to activate the perfusion pump. Our study used basic and animal experiments to investigat...

متن کامل

A randomized comparison of intra-aortic balloon pumping after primary coronary angioplasty in high risk patients with acute myocardial infarction.

AIMS Intra-aortic balloon pumping reduces afterload and may be effective in improving reperfusion in high risk infarct patients treated with primary angioplasty. METHODS High risk infarct patients referred from other centres for primary PTCA were randomized to treatment with or without an intra-aortic balloon pump. The primary end-point consisted of the combination of death, non-fatal reinfar...

متن کامل

Biventricular pacing in conjunction with epicardial atrial pacing adversely affects timing of intra-aortic balloon pump.

A case of accidental triggering of an intra-aortic balloon pump during systole is presented. The patient had a cardiac resynchronization therapy device in place preoperatively for heart failure. A temporary epicardial atrial pacing wire was used during separation from cardiopulmonary bypass for rate control. An intra-aortic balloon pump was necessary for separation from bypass. Although the pac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2014