Assessment of lower-voltage TEM performance using 3D Fourier transform of through-focus series.
نویسندگان
چکیده
We assess the imaging performance of a transmission electron microscopy (TEM) system operated at a relatively low acceleration voltage using the three-dimensional (3D) Fourier transform of through-focus images. Although a single diffractogram and the Thon diagram cannot distinguish between the linear and non-linear TEM imaging terms, the 3D Fourier transform allows us to evaluate linear imaging terms, resulting in a conclusive assessment of TEM performance. Using this method, information transfer up to 98 pm is demonstrated for an 80 kV TEM system equipped with a spherical aberration corrector and a monochromator. We also revisit the Young fringe method in the light of the 3D Fourier transform, and have found a considerable amount of non-linear terms in Young fringes at 80 kV even from a typical standard specimen, such as an amorphous Ge thin film.
منابع مشابه
Residual analysis using Fourier series transform in Fuzzy time series model
In this paper, we propose a new residual analysis method using Fourier series transform into fuzzy time series model for improving the forecasting performance. This hybrid model takes advantage of the high predictable power of fuzzy time series model and Fourier series transform to fit the estimated residuals into frequency spectra, select the low-frequency terms, filter out high-frequency term...
متن کامل3D Models Recognition in Fourier Domain Using Compression of the Spherical Mesh up to the Models Surface
Representing 3D models in diverse fields have automatically paved the way of storing, indexing, classifying, and retrieving 3D objects. Classification and retrieval of 3D models demand that the 3D models represent in a way to capture the local and global shape specifications of the object. This requires establishing a 3D descriptor or signature that summarizes the pivotal shape properties of th...
متن کاملImpedance Control of Robots Using Voltage Control Strategy Revisited
In this note, we show that the impedance control strategy proposed in the paper is not feasible from practical implementation point of view. Next, a robust impedance controller is proposed for electrically driven robots using Fourier series (FS). The fact that robots' actuators have limited voltage is also considered in controller design procedure. In comparison with other impedance controllers...
متن کاملDetecting buried channels using linear least square RGB color stacking method based on deconvolutive short time Fourier transform
Buried channels are one of the stratigraphic hydrocarbon traps. They are often filled with a variety of porous and permeable sediments so they are important in the exploration of oil and gas reservoirs. In reflection seismic data, high-frequency components are sensitive to the channel thickness, whereas, low-frequency components are sensitive to the channel infill materials. Therefore, decompos...
متن کاملمعرفی و شبیه سازی روش جدید اندازه گیری ضریب تلفات عایقی و پرمتیویته نسبی
For evaluating quality of electrical insulation, it is necessary to measure the property of insulators. Dielectric constant and loss tangent (tans) are two important parameters for determining the property of insulator. The measurement of above parameters is normally based on the time- domain and frequency-domain, which is costly and time consuming. In this study a multiple-frequency binary se...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultramicroscopy
دوره 121 شماره
صفحات -
تاریخ انتشار 2012