Effect of implant-abutment connection design on reliability of crowns: regular vs. horizontal mismatched platform.
نویسندگان
چکیده
OBJECTIVES To evaluate the reliability and failure modes of regular and horizontal mismatched platforms for implant-abutment connection varying the implant diameter. MATERIAL AND METHODS Regular (REG, n = 21, 4.0-mm-diameter implant) and horizontal mismatched (HM, n = 21, 4.6-mm-diameter implant) platform Ti-6Al-4V implants were restored with proprietary identical Ti-6Al-4V abutments and metal crowns (cobalt-chrome, Wirobond 280, BEGO, Bremen, Germany) cemented. Mechanical testing comprised step-stress accelerated-life testing, where crowns were distributed in three loading profiles for fatigue in water, producing timely and clinically relevant fractures. The probability of failure vs. cycles (95% two-sided confidence intervals) was calculated and plotted using a powerlaw relationship for damage accumulation, Weibull modulus (95% two-sided confidence intervals) and then the reliability for a mission of 50,000 cycles at 125 N load (95% two-sided confidence interval) were calculated. Fractography was performed in the scanning electron microscope. RESULTS The β-value for group REG (β = 1.37) indicated that fatigue was a factor accelerating the failure, whereas load alone dictated the failure for group HM (β = 0.71). The Weibull parameter contour plot showed no significantly different Weibull modulus for REG (10.24) compared to HM (10.20) and characteristic strength of 162.6 and 166.8 N, respectively (P > 0.91). The calculated reliability for a mission of 50,000 cycles at 125 N load was not significantly different (0.71 for REG and 0.73 for HM). Abutment screw failure was the chief failure mode. CONCLUSIONS Reliability was not significantly different between groups and failure modes were similar.
منابع مشابه
Effect of implant connection and restoration design (screwed vs. cemented) in reliability and failure modes of anterior crowns.
The mechanical performance of cemented or screw-retained implant-supported crowns with an internal or external configuration is yet to be understood. This in vitro study evaluated the effect of screw-retained and cement-retained prostheses on internal and external implant-abutment connections. Thereby, the reliability and failure modes of crowns were investigated. Eighty-four implants (Emfils; ...
متن کاملThe Effect of Abutment Surface Roughness on the Retention of Implant-Supported Crowns Cemented with Provisional Luting Cement
Introduction: Surface roughness can increase the retention of castings by ridges and grooves that are microretentive. This study compared the retention of implant-supported crowns when used with 3 different surface roughness abutments and one temporary cement. Methods: Thirty solid abutments (ITI), 4 mm high, were divided into three groups randomly. In the first group, 10 abutments were roughen...
متن کاملمقایسه تشخیص رادیوگرافیک عدم تطابق اباتمنتهای زیرکونیایی و تیتانیومی در سه نوع مختلف ناحیه اتصال
Background and Aims: In response to esthetic demand and use of zirconia abutments; detection of implant-abutment connection misfit is so important. The purpose of this study was to evaluate the sensitivity and specificity of radiographic images in the detection of abutment-implant connection misfit in zirconia and titanium abutments of three different implant connections. Materials and Met...
متن کاملMatched and Platform-Switched Implants - A Prospective Study
of the effect of platform-switching on marginal bone loss (MBL) around dental implants. Forty patients requiring a dental implant in non-grafted partially edentulous mandibles were enrolled and categorized into implants receiving a platform-matched abutment (control group) or implants with a platform-switched abutment (test group). Standardized digital periapical radiographs were taken at the t...
متن کاملComparison of fit accuracy and torque maintenance of zirconia and titanium abutments for internal tri-channel and external-hex implant connections
PURPOSE This in vitro study aimed to evaluate the effect of implant connection design (external vs. internal) on the fit discrepancy and torque loss of zirconia and titanium abutments. MATERIALS AND METHODS Two regular platform dental implants, one with external connection (Brånemark, Nobel Biocare AB) and the other with internal connection (Noble Replace, Nobel Biocare AB), were selected. Se...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical oral implants research
دوره 23 9 شماره
صفحات -
تاریخ انتشار 2012