Whole Body MRI Intensity Standardization

نویسندگان

  • Florian Jäger
  • László G. Nyúl
  • Bernd B. Frericks
  • Frank K. Wacker
  • Joachim Hornegger
چکیده

A major problem of segmentation of magnetic resonance images is that intensities are not standardized like in computed tomography. This article deals with the correction of inter volume intensity differences that lead to a missing anatomical meaning of the observed gray values. We present a method for MRI intensity standardization of whole body MRI scans. The approach is based on the alignment of a learned reference and the current histogram. Each of these histograms is at least 2-d and represents two or more MRI sequences (e.g., T1and T2-weighted images). From the matching a non-linear correction function is gained which describes a mapping between the intensity spaces and consequently adapts the image statistics to a known standard. As the proposed intensity standardization is based on the statistics of the data sets only, it is independent from spatial coherences or prior segmentations of the reference and newly acquired images. Furthermore, it is not designed for a particular application, body region or acquisition protocol. The method was evaluated on whole body MRI scans containing data sets acquired by T1/FL2D and T2/TIRM sequences. In order to demonstrate the applicability, examples from noisy and pathological image series acquired on a whole body MRI scanner are given.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tissue-Based MRI Intensity Standardization: Application to Multicentric Datasets

Intensity standardization in MRI aims at correcting scanner-dependent intensity variations. Existing simple and robust techniques aim at matching the input image histogram onto a standard, while we think that standardization should aim at matching spatially corresponding tissue intensities. In this study, we present a novel automatic technique, called STI for STandardization of Intensities, whi...

متن کامل

Inter‐station intensity standardization for whole‐body MR data

PURPOSE To develop and validate a method for performing inter-station intensity standardization in multispectral whole-body MR data. METHODS Different approaches for mapping the intensity of each acquired image stack into the reference intensity space were developed and validated. The registration strategies included: "direct" registration to the reference station (Strategy 1), "progressive" ...

متن کامل

MR intensity standardization and fuzzy segmentation of MR images

Lifetime from: 1997 Lifetime to: 2000 Short description: We developed an image processing method for MRI intensity standardization. We also introduced new, fast implementations of the fuzzy connectedness algorithm that allows segmentation at interactive speeds. We developed a new segmentation "workshop" for brain MRI segmentation using standardized MR images and the fast fuzzy connectedness alg...

متن کامل

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

Intensity non-standardness affects computer recognition of anatomical structures

Since MR image intensities do not possess a tissue specific numeric meaning, even in images acquired for the same subject, on the same scanner, for the same body region, by using the same pulse sequence, it is important to transform the image scale into a standard intensity scale so that, for the same body region, intensities are similar. The lack of a standard image intensity scale in MRI lead...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007