Lack of agreement between different observers and methods in the measurement of capillary refill time in healthy volunteers: an observational study
نویسندگان
چکیده
OBJECTIVE Peripheral perfusion abnormalities are relevant manifestations of shock. Capillary refill time is commonly used for their evaluation. However, the reproducibility of capillary refill time measurements and their correlation with other variables of peripheral perfusion, have not been comprehensively evaluated. Our goal was to determine, in healthy volunteers, the agreement between different methods of capillary refill time quantification and different observers, as well as their correlation with other markers of peripheral perfusion. Methods: We studied 63 healthy volunteers. Two observers measured capillary refill time by means of two methods, direct view (CRTchronome ter) and video analysis (CRTvideo). We also measured perfusion index (PI) derived from pulse plethysmography and finger pad temperature (T°peripheral). The agreement between observers and methods was assessed using the Bland and Altman method. Correlations were calculated using Pearson's correlation. A p-value<0.05 was considered significant. RESULTS The 95% limits of agreement between the two observers were 1.9 sec for CRTchronometer and 1.7 sec for CRTvideo. The 95% limits of agreement between CRTchronometer and CRTvideo were 1.7 sec for observer 1 and 2.3 sec for observer 2. Measurements of CRTchronometer performed by the two observers were correlated with T°peripheral. Measurements of CRTvideo performed by the two observers were correlated with T°peripheral and perfusion index. CONCLUSION In healthy volunteers, measurements of capillary refill time performed by either different observers or different methods showed poor agreement. Nevertheless, capillary refill time still reflected peripheral perfusion as shown by its correlation with objective variables of peripheral perfusion.
منابع مشابه
بررسی پایایی چک لیست ارگونومیکی ایالت واشنگتن با روش توافق بین مشاهدهکنندگان در دو گروه متخصص و غیرمتخصص در ارگونومی
Background & Objectives: Assessment of physical risk factors related to musculoskeletal disorders is performed by different methods including observational methods. Validity of these methods are important in workplaces. The purpose of this study was to investigate the reliability of the Washington States ergonomics checklist as an observational method. Methods: This descriptive-analytic...
متن کاملAre bedside features of shock reproducible between different observers?
Shock is often under-reported in children attending hospitals in developing countries. Readily obtainable features of shock (capillary refill time, temperature gradient, pulse volume, and signs of dehydration) are widely used to help prioritise management in the emergency assessment of critically ill or injured children. However, data are lacking on their validity, including, importantly, repro...
متن کاملValidity and reliability of measurement of capillary refill time in children: a systematic review.
BACKGROUND Most guidelines recommend the use of capillary refill time (CRT) as part of the routine assessment of unwell children, but there is little consensus on the optimum method of measurement and cut-off time. METHODS We searched Medline (from 1948), Embase (from 1980) and CINAHL (from 1991) to June 2014 to identify studies with information on the normal range of CRT in healthy children,...
متن کاملAccuracy of an Intraoral Digital System for File Length Measurement
Introdouction: Canal length measurement is essential for proper endodontic treatment. Any error or miscalculation in working length determination, particularly in curved canals, can result in complications during or after root canal therapy. Digital radiography has enabled accurate measurement of curved canal length. In this study, we evaluated the accuracy of calibration of a complementary m...
متن کاملطراحی و ارزیابی روایی و پایایی وسیلهای برای اندازهگیری زاویه تقارب سطوح اگزیال دندانهای تراشخورده در پروتزهای ثابت متکی بر دندان
Background and Aims: The purpose of this study was to design a new device assisting dental students to measure the tapering of the prepared teeth for fixed crown prosthesis in which the desired tapering for better clinical prognosis could be obtained. Materials and Methods: The designed device in this study had two arms that were placed on two opposite walls of the prepared teeth. To evaluate ...
متن کامل