Reconstruction of 4D-CT from a Single Free-Breathing 3D-CT by Spatial-Temporal Image Registration
نویسندگان
چکیده
In the radiation therapy of lung cancer, a free-breathing 3D-CT image is usually acquired in the treatment day for image-guided patient setup, by registering with the free-breathing 3D-CT image acquired in the planning day. In this way, the optimal dose plan computed in the planning day can be transferred onto the treatment day for cancer radiotherapy. However, patient setup based on the simple registration of the free-breathing 3D-CT images of the planning and the treatment days may mislead the radiotherapy, since the free-breathing 3D-CT is actually the mixed-phase image, with different slices often acquired from different respiratory phases. Moreover, a 4D-CT that is generally acquired in the planning day for improvement of dose planning is often ignored for guiding patient setup in the treatment day. To overcome these limitations, we present a novel two-step method to reconstruct the 4D-CT from a single free-breathing 3D-CT of the treatment day, by utilizing the 4D-CT model built in the planning day. Specifically, in the first step, we proposed a new spatial-temporal registration algorithm to align all phase images of the 4D-CT acquired in the planning day, for building a 4D-CT model with temporal correspondences established among all respiratory phases. In the second step, we first determine the optimal phase for each slice of the free-breathing (mixed-phase) 3D-CT of the treatment day by comparing with the 4D-CT of the planning day and thus obtain a sequence of partial 3D-CT images for the treatment day, each with only the incomplete image information in certain slices; and then we reconstruct a complete 4D-CT for the treatment day by warping the 4D-CT of the planning day (with complete information) to the sequence of partial 3D-CT images of the treatment day, under the guidance of the 4D-CT model built in the planning day. We have comprehensively evaluated our 4D-CT model building algorithm on a public lung image database, achieving the best registration accuracy over all other state-of-the-art methods. Also, we have validated our proposed 4D-CT reconstruction algorithm on the simulated free-breathing data, obtaining very promising 4D-CT reconstruction results.
منابع مشابه
AbstractID: 4788 Title: Model-based statistical image reconstruction for 4D PET
ID: 4788 Title: Model-based statistical image reconstruction for 4D PET Purpose: Four-dimensional (4D) PET can be acquired with gated, dynamic or list mode. In reality, a major problem limiting its clinical application is the poor statistics, since the total coincidence counts in conventional 3D PET are divided into several phase bins and each of them is treated as an independent entity in 4D i...
متن کاملLung Deformation Estimation and Four-dimensional CT Lung Reconstruction1
Rationale and Objectives. Four-dimensional (4D) computed tomography (CT) can be used in radiation treatment planning to account for respiratory motion. Current 4D CT techniques have limitations in either spatial or temporal resolution. In addition, most of these techniques rely on auxiliary surrogates to relate the time of the CT scan to the patient’s respiratory phase. We propose a 4D CT metho...
متن کاملFeasibility and potential benefits of defining the internal gross tumor volume of hepatocellular carcinoma using contrast-enhanced 4D CT images obtained by deformable registration
OBJECTIVE To study the feasibility and the potential benefits of defining the internal gross tumor volume (IGTV) of hepatocellular carcinoma (HCC) using contrast-enhanced 4D CT images obtained by combining arterial-phase (AP) contrast-enhanced (CE) 3D CT and non-contrast-enhanced (NCE) 4D CT images using deformable registration (DR). METHODS Ten HCC patients who had received radiotherapy befo...
متن کاملروشی جدید برای تطبیق تصاویر پزشکی همنوع برپایه مدلهای دگردیسپذیر و کاربرد آن برای تصاویر CT قفسه سینه
In 4D CT images of the thorax, deformation is caused by both the tissue movement and breathing. Tissue movement can be estimated at various time intervals by image registrstion. In this paper, a new deformable model is proposedfor non-regid medical image resgistration. The energy funational of the suggested algorithm consists of two internal (regulator) and external terms. By minimization of th...
متن کاملImproving iterative 4D CBCT through the use of motion information
In Image-Guided RadioTherapy (IGRT) of lung tumors, patients undergo a 4D CT, on the basis of which their treatment is planned. It is implicitely assumed that their breathing motion will not change much throughout the treatment, and remain close to what it was during the 4D CT acquisition. During the treatment, several cone beam CT acquisitions are performed, and used to re-position the patient...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Information processing in medical imaging : proceedings of the ... conference
دوره 22 شماره
صفحات -
تاریخ انتشار 2011