Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study

نویسندگان

  • Laura Martinez-Mateu
  • Lucia Romero
  • Ana Ferrer-Albero
  • Rafael Sebastian
  • José F Rodríguez Matas
  • José Jalife
  • Omer Berenfeld
  • Javier Saiz
چکیده

Anatomically based procedures to ablate atrial fibrillation (AF) are often successful in terminating paroxysmal AF. However, the ability to terminate persistent AF remains disappointing. New mechanistic approaches use multiple-electrode basket catheter mapping to localize and target AF drivers in the form of rotors but significant concerns remain about their accuracy. We aimed to evaluate how electrode-endocardium distance, far-field sources and inter-electrode distance affect the accuracy of localizing rotors. Sustained rotor activation of the atria was simulated numerically and mapped using a virtual basket catheter with varying electrode densities placed at different positions within the atrial cavity. Unipolar electrograms were calculated on the entire endocardial surface and at each of the electrodes. Rotors were tracked on the interpolated basket phase maps and compared with the respective atrial voltage and endocardial phase maps, which served as references. Rotor detection by the basket maps varied between 35-94% of the simulation time, depending on the basket's position and the electrode-to-endocardial wall distance. However, two different types of phantom rotors appeared also on the basket maps. The first type was due to the far-field sources and the second type was due to interpolation between the electrodes; increasing electrode density decreased the incidence of the second but not the first type of phantom rotors. In the simulations study, basket catheter-based phase mapping detected rotors even when the basket was not in full contact with the endocardial wall, but always generated a number of phantom rotors in the presence of only a single real rotor, which would be the desired ablation target. Phantom rotors may mislead and contribute to failure in AF ablation procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical mapping approach to diagnose electrical rotors and focal impulse sources for human atrial fibrillation.

INTRODUCTION The perpetuating mechanisms for human atrial fibrillation (AF) remain undefined. Localized rotors and focal beat sources may sustain AF in elegant animal models, but there has been no direct evidence for localized sources in human AF using traditional methods. We developed a clinical computational mapping approach, guided by human atrial tissue physiology, to reveal sources of huma...

متن کامل

Localized rotors and focal impulse sources within the left atrium in human atrial fibrillation: A phase analysis of contact basket catheter electrograms

BACKGROUND Consistent detection of rotor(s) and/or focal impulse(s) of atrial fibrillation can using a 64-pole basket catheter remain unclear. METHODS AND RESULTS Intracardiac left atrial electrograms were recorded, prior to ablation, in 20 patients with atrial fibrillation. Unipolar electrograms, filtered at 0.1-300 Hz, were recorded and exported for an offline phase analysis. From the cohor...

متن کامل

Improved Semi-Automatic Basket Catheter Reconstruction from two X-Ray Views

Ablation guided by focal impulse and rotor mapping (FIRM) is an alternative treatment for atrial fibrillation in particular for persistent atrial fibrillation. To this end, a basket catheter comprising 64 electrodes is inserted into both the right atrium and left atrium under X-ray guidance to locate electric anomalies. The 3-D positions of the electrodes are needed to determine the ablation re...

متن کامل

Semi-Automatic Basket Catheter Reconstruction from Two X-Ray Views

Ablation guided by focal impulse and rotor mapping (FIRM) is a novel treatment option for atrial fibrillation, a frequent heart arrhythmia. This procedure is performed minimally invasively and at least partially under fluoroscopic guidance. It involves a basket catheter comprising 64 electrodes. The 3-D position of these electrodes is important during treatment. We propose a novel model-based m...

متن کامل

Process Improvement of Experimental Measurements Using D-optimal Models

In this paper, the application of D-optimal models, as an alternative to response surface models (RS models) for design of experiment (DOE) was examined. Two D-optimal models for tilt-rotors in the wind tunnel experiment, as a form of quadratic functions, were generated based on a chosen optimality criterion. This optimality criterion was used to generate the optimized sampled points in the des...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2018