Fiducial point placement and the accuracy of point-based, rigid body registration.

نویسندگان

  • J B West
  • J M Fitzpatrick
  • S A Toms
  • C R Maurer
  • R J Maciunas
چکیده

OBJECTIVE To demonstrate that the shape of the configuration of fiducial points is an important factor governing target registration error (TRE) in point-based, rigid registration. METHODS We consider two clinical situations: cranial neurosurgery and pedicle screw placement. For cranial neurosurgery, we apply theoretical results concerning TRE prediction, which we have previously derived and validated, to three hypothetical fiducial marker configurations. We illustrate the profile of expected TRE for each configuration. For pedicle screw placement, we apply the same theory to a common anatomic landmark configuration (tips of spinous and transverse processes) used for pedicle screw placement, and we estimate the error rate expected in placement of the screw. RESULTS In the cranial neurosurgery example, we demonstrate that relatively small values of TRE may be achieved by using widely spread fiducial markers and/or placing the centroid of the markers near the target. We also demonstrate that near-collinear marker configurations far from the target may result in large TRE values. In the pedicle screw placement example, we demonstrate that the screw must be approximately 4 mm narrower than the pedicle in which it is implanted to minimize the chance of pedicle violation during placement. CONCLUSION The placement of fiducial points is an important factor in minimizing the error rate for point-based, rigid registration. By using as many points as possible, avoiding near-collinear configurations, and ensuring that the centroid of the fiducial points is as near as possible to the target, TREs can be minimized.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Derivation of Expected Registration Error for Point-based Rigid-body Registration

This paper presents two new expressions for estimating registration accuracy in point-based rigid-body registration and points out a danger in using the traditional measure of registration accuracy. Rigid-body registration is appropriate for applications in which relatively rigid parts of the body are involved. In some such applications rigid-body registration is accomplished by aligning two se...

متن کامل

The distribution of registration error of a fiducial marker in rigid-body point-based registration

Many image-guidance surgical systems rely on rigid-body, point-based registration of fiducial markers attached to the patient. Marker locations in image space and physical space are used to provide the transformation that maps a point from one space to the other. Target registration error (TRE) is known to depend on the fiducial localization error (FLE), and the fiducial registration error (FRE...

متن کامل

Fiducial markers configuration optimization in image-guided surgery.

The rigid registration is a key step of Image Guided Surgery (IGS), and the point-pair method is the main way used for registration. However the configuration of fiducial points has a great influence on the registration accuracy at the target point. Now almost all the optimization method of fiducial points configuration relies on the empirical simulation-based Fitzpatrick's target registration ...

متن کامل

Comparing Different Strategies about Optimal Marker Placement in Image-Guided Neurosurgery

Image-Guided Neurosurgery (IGNS) has become a widely exploited technique in the neurosurgical operating room in recent years, due to its reliability and low invasiveness [1]. In particular, minimal invasive neurosurgery is essential in key-hole interventions, where brain shift can be neglected: for example, the aspiration of intracranial hematomas, the catheter insertion, and deep brain stimula...

متن کامل

Rigid point registration circuits

In 1996 Freeborough proposed a method for estimating target registration error (TRE) in the absence of ground truth. In his approach, a circuit of registrations is performed using the same registration method on multiple views of the same object: 1 to 2, 2 to 3, ..., NC –1 to NC , and NC to 1 where NC is at least three and the last registration completes the circuit. Any difference between the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Neurosurgery

دوره 48 4  شماره 

صفحات  -

تاریخ انتشار 2001