The arthroscopic-assisted removal of a distal femoral condylar locking plate--a case report.

نویسندگان

  • Nicholas Garbis
  • Carlos A Uquillas
  • Eric J Strauss
  • Bernard R Bach
چکیده

We describe a minimally invasive procedure for removal of a distal femur locking plate using arthroscopic assistance. Using lateral accessory portals, we performed arthroscopically-assisted removal of distal locking screws. Under fluoroscopic image, proximal screws were removed from the diaphysis. The accessory lateral portal sites used to remove the distal screws were connected. Through this arthrotomy, the plate was elevated from the distal femur and removed without difficulty. With this method we were able to concomitantly visualize the intra-articular regions while accomplishing the hardware removal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Failure of Distal Femoral Locking Plate: Case Report

The Less Invasive Stabilization System (LISS) and titanium distal femoral locking compression plate (DF-LCP) was designed by the AO Group to combine the advantages of both interlocked intra-medullary nailing and biological plating techniques in one system. The stiffness of the construct is similar to a 95° condylar plate, dynamic condylar screw, or condylar buttress plate. We report a case of t...

متن کامل

Femoral Condyle Fracture during Anterior Cruciate Ligament Reconstruction

Dear Editor,We have greatly enjoyed reading the case report entitled “‘Femoral Condyle Fracture during Revision of Anterior Cruciate Ligament Reconstruction: Case Report and a Review of Literature in the issue of Arch Bone Jt Surg. 2015;3(2) with great interest. We would like to commend the authors for their detailed and valuable work. Although various case reports have described postoperative ...

متن کامل

Supracondylar Osteotomy in Valgus Knee: Angle Blade Plate Versus Locking Compression Plate

  Background: There are few studies comparing the biomechanical properties of angled blade plate and locking compression plates in supracondylar osteotomy. In the current randomized study, we prospectively compared the clinical and radiological outcomes of supracondylar osteotomy using these two plates. Methods: Forty patients with valgus knee malalignment were randomly assigned to two equal nu...

متن کامل

Is Distal Femur Locking Plate a Superior Implant in Distal Femur Fracture?

In spite of advances in techniques and improvements in surgical implants, confusion still prevails regarding use of specific implants in distal femur fracture. Fractures in the distal femur have posed considerable therapeutic challenges throughout the history of fracture treatment. Most of these surgical failures were due to inadequate fixation of the fracture fragments. The Aim of the study is...

متن کامل

Femoral Condyle Fracture during Revision of Anterior Cruciate Ligament Reconstruction: Case Report and a Review of Literature

 Background: A rare and devastating complication following anterior cruciate ligament (ACL) revision reconstruction is femoral fracture.    Case presentation: A 35-year old male soccer player with a history of ACL tear from the previous year ago, who underwent arthroscopic ACL reconstruction and functioned well until another similar injury caused ACL re-rupture. Revision of ACL reconstruction w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bulletin of the Hospital for Joint Disease

دوره 72 2  شماره 

صفحات  -

تاریخ انتشار 2014