Radiographic Assessment of Guided Growth: The Correlation Between Screw Divergence and Change in Anatomic Alignment.
نویسندگان
چکیده
BACKGROUND Assessment of changes in anatomic alignment following guided growth traditionally utilizes full-length standing radiographs which subjects patients to larger radiation doses than does a single anteroposterior radiograph of the knee. In an effort to minimize radiation exposure, the present study sought to determine whether changes in screw divergence (SD) of the 2-hole tension band plate used for hemiepiphysiodesis reliably predicts change in alignment. METHODS A retrospective review was conducted involving all patients with genu varum or genu valgum treated with hemiepiphysiodesis at a single institution. Preoperative anatomic alignment of the femur, using anatomic lateral distal femoral angle (aLDFA) and anatomic femoral-tibial angle (aTFA), and intraoperative divergence of hemiepiphysiodesis screws were compared with postoperative imaging. Linear regression analysis determined the relationship between changes in SD and changes in alignment, and multivariate regression analysis explored the relationship between the angular changes being measured and various demographic factors. RESULTS Linear regression analysis revealed that for every 1 degree change in SD there was a resultant 1.80 degrees of change in aTFA and 2.11 degrees of change in aLDFA. Change in aTFA is predicted by the equation: [INCREMENT]aTFA=0.41×|[INCREMENT]SD|+1.39. The change in aLDFA was predicted by the equation [INCREMENT]aLDFA=0.27×[INCREMENT]SD+1.84 with a R2 of 0.31. [INCREMENT]aTFA and [INCREMENT]SD had a correlation coefficient of 0.68 (95% confidence interval, 0.54-0.78.) [INCREMENT]aLDFA and [INCREMENT]SD had a correlation coefficient of 0.56 (95% confidence interval, 0.42-0.68). [INCREMENT]SD and sex were the only 2 independent predictors for [INCREMENT]aLDFA and [INCREMENT]aTFA as determined by multivariate regression analysis. CONCLUSION Change in coronal plane anatomic alignment in patients being treated for genu valgum or genu varum with hemiepiphysiodesis can be reasonably estimated by measuring the change in SD. Therefore, when following patients postoperatively, focal radiographic imaging of the knee can be utilized in lieu of standing full-length limb radiographs to limit radiation to the pelvis in this sensitive patient population. LEVEL OF EVIDENCE Level III-retrospective comparative study.
منابع مشابه
"Divergence problem" in estimating temperature based on tree rings (Case study: Juniper mountainous habitats in northern Kerman province)
Introduction The study of tree rings is one of the most widely used methods of climate reconstruction for centuries and millennia, but the occurrence of climatic anomalies such as global warming in recent decades has caused divergence problem in the series of tree rings in some areas. Which challenges the ability of this proxy to regenerate the climate. The “divergence problem” is the differen...
متن کاملValidation of Goniometric Method in the Assessment of Lordosis by Radiographic Analysis
Background & Aims: Cervical spine is prone to various abnormalities and sport injuries. There is still no non-aggressive measurement instrument with high reliability for easy and rapid assessment of cervical spine secondary complications. The aim of this research was to investigate the validity of goniometric method for cervical lordosis measurement through radiography. Method: In this study, 1...
متن کاملThe Results of Biplanar Distal Femoral Osteotomy; A Case Series Study
Background: Distal femur wedge osteotomies for varus or valgus alignment of the lower extremity could be done in either uniplanar or biplanar fashion.Union time and stability of the osteotomy site has been considered important in this anatomic region. In this study, clinical and radiographic findings of biplane distal femur osteotomy were reported. Methods: Clinical, functional, and radiologic...
متن کاملThe Impact of Residual Geometric Inaccuracies on Normal Organ Doses in Image Guided-Radiation Therapy of Prostate Cancer Using On-Board Kilovoltage Cone-Beam Computed Tomography
Introduction: The aim of this retrospective study was to evaluate the variations in delivered dose to the bladder, rectum, and femoral heads of prostate cancer patients during a course of treatment by image-guided radiation therapy (IGRT). Materials and Methods: Overall, 15 patients with prostate cancer were selected and. Each week, for each patient five consecutive cone beam computed tomograph...
متن کاملComparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation
Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of pediatric orthopedics
دوره 37 4 شماره
صفحات -
تاریخ انتشار 2017