Comments on Evaluation Tc Tc -comments on Evaluation of Decay Data by X. Mougeot 1 Decay Scheme 2 Nuclear Data Tc Half-life
نویسنده
چکیده
The evaluation of the 99Tc half-life is described in the next section. Table 2 summarizes the measurements and their methodology. Although the β-decay of 99Tc is practically 100 % from its 9/2+ ground state to the 5/2+ ground state of 99Ru, 1973LE10 and 1974EN02 observed a β-decay with a very small intensity to the 3/2+ first excited state of 99Ru. Thus, its energy, half-life and the multipolarity of the de-exciting γ-ray are evaluated. The βbranching ratio is evaluated next. An analysis of the published form factors of the main βtransition is presented here. With the described limitations, an evaluation was carried out and the mean energy of the spectrum was calculated.
منابع مشابه
Evaluation of Patients’ effective dose in nuclear medicine department of Isfahan in order to define a local reference level
Introduction: Nowadays, nuclear medicine (NM) imaging indications in medical practice is raising. A practical step to get closer to the optimization rule is collecting data about patients’ exposure and definition of guidance levels. The aim of this study was definition of local reference level in Isfahan city. Materials and Methods: Questionnaires were given...
متن کاملTc-99m-Pertechnetate in evaluation of meckel's diverticulum [Persian]
Meckel's diverticulum is a common congenital disorder which may result in Gl bleeding. For definite diagnosis before surgery, radiographic procedures such as small intestine barium studies are not greatly successful; on the other hand Tc-99m-Pertechnetate imaging is a physiologic and noninvasive method with high sensitivity and specificity. In this report, three patients with rectorrhagia...
متن کاملTc-99m-MIBI in evaluation of myocardial perfusion [Persian]
Tc-99m-MIBI is an isonrtrile derivative used for evaluation of myocardial perfusion in recent years. In this preliminary report, 7 patients with coronary artery disease are evaluated with Tc-99m-MlBl stress planar and sped studies. Good correlation with coronary angiography is observed in these cases. In view of inherent technical problems present with thallium 201, Tc-99m-MIBi is a good ...
متن کاملComparison of Tc-99m Ethylenedicysteine (Tc-99m EC) with Tc-99m DPTA in evaluation of renal disease [Persian]
Tc-99m-EC is a new renal radiopharmaceutical introduced as an alternative for Tc-99m MAG3. Twenty-three normal volunteers and patients in different .stages of renal disease were evaluated with Te-99m EC and Tc-99m DTPA. The mean initial uptake of EC was significantly higher as compared to DTPA. There was a high correlation between rectangular and hand-drawn ROls for kidney and background,...
متن کاملSinus Tarsi Syndrome: Diagnosed on 99m-Tc MDP Bone SPECT/CT
Sinus Tarsi Syndrome is a cause of chronic ankle instability and pain. MRI of the ankle has been the modality of choice for diagnosing the condition. However, SPECT-CT offers an alternate modality for diagnosing and evaluation of the condition. We present the case of a footballer who was suffering from chronic right leg pain despite receiving physiotherapy. He was being managed as a case of a c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2010