The purpose of a drinking water distribution system is to deliver drinking water to the consumer, preferably with the same quality as when it left the treatment plant. In this context, the maintenance of good microbiological quality is often referred to as biological stability, and the addition of sufficient chlorine residuals is regarded as one way to achieve this. The full-scale drinking water distribution system of Riga (Latvia) was investigated with respect to biological stability in chlorinated drinking water. Flow cytometric (FCM) intact cell concentrations, intracellular adenosine tri-phosphate (ATP), heterotrophic plate counts and residual chlorine measurements were performed to evaluate the drinking water quality and stability at 49 sampling points throughout the distribution network. Cell viability methods were compared and the importance of extracellular ATP measurements was examined as well. FCM intact cell concentrations varied from 5×10(3) cells mL(-1) to 4.66×10(5) cells mL(-1) in the network. While this parameter did not exceed 2.1×10(4) cells mL(-1) in the effluent from any water treatment plant, 50% of all the network samples contained more than 1.06×10(5) cells mL(-1). This indisputably demonstrates biological instability in this particular drinking water distribution system, which was ascribed to a loss of disinfectant residuals and concomitant bacterial growth. The study highlights the potential of using cultivation-independent methods for the assessment of chlorinated water samples. In addition, it underlines the complexity of full-scale drinking water distribution systems, and the resulting challenges to establish the causes of biological instability.
منابع مشابه
بررسی غلظت کلروفرم در آب شرب تهران در سال 1388
Background and purpose: Chloroform is a disinfection byproducts (DBPs) that results from reactions between residual chlorine and organic compounds as precursors. The presence of these DBPs in chlorinated drinking water can pose a severe public health threat including potential carcinogenicity. In this study chloroform concentrations as an indicator of DBPs of chlorinated water was evaluated in ...
متن کاملEffect of pH, Chlorine Residual and Turbidity on the Microbial Bio Indicators of Drinking Water Network
Abstract Background and objective: Bioindicators of drinking water are always influenced by physical and chemical factors such as turbidity and chlorine. Considering the assessment of drinking water quality is based on residual chlorine, E.coli, heterotrophic bacteria and turbidity. We aimed to evaluate the effect of pH, chlorine residual and turbidity on the microbial ...
متن کاملCarcinogen Risk Assessment of Mutagen X in Chlorinated Drinking Water in West of Tehran, Using Probabilistic Approaches
The present study aims at evaluating the risk of Mutagen X (MX) (3-chloro-4-(dichloromethyl)-5-hydroxy-2 (5H)-furanone) and adverse health effects, associated with direct ingestion of chlorinated drinking water in west of Tehran, supplied by chlorinated drinking water from surface and underground water sources. For one year, MX concentrations in tap water samples has been measured for consumers...
متن کاملEvaluation of Cadmium, Arsenic and Mercury Concentrations in the Drinking Water Distribution Network in Ardabil City in 2018
Background & objectives: Heavy metals enter water sources in many ways and cause hazards such as poisoning and carcinogenesis in the living organisms. This study aimed to investigate the concentration of heavy metals (arsenic, mercury, and cadmium) in the Yamchi Reservoir Dam and Ardabil drinking water distribution network in high and low rainfall seasons in 2018. Methods: In this cross-sectio...
متن کاملDetermining suitable model for zoning drinking water distribution network based on corrosion potential in Sanandaj City, Iran
Corrosion in general is a complex interaction between water and metal surfaces and materials in which the water is stored or transported. Water quality monitoring in terms of corrosion and scaling is crucial, and a key element of preventive maintenance, given the economic and health hurts caused by corrosion and scaling in water utilities. The aim of this study is to determine the best model fo...
متن کامل