Simultaneous identification of the enantiomers and diastereomers of N,O-di-trifluoroacetylated ephedrine and norephedrine in blood plasma using chiral capillary gas chromatography-mass spectrometry with selected ion monitoring.

نویسندگان

  • Toshiaki Nagai
  • Akira Kurosu
  • Kazumi Matsushima
  • Junko Maeda
  • Atsushi Tohei
  • Shinobu Yamauchi
  • Masahito Hitosugi
  • Shogo Tokudome
چکیده

A method for identifying the enantiomers of N,O-di-trifluoroacetylated ephedrine (EP) and norephedrine (NE) and the enantiomers of pseudoephedrine (PEP) and pseudonorephedrine (PNE) in plasma was developed using chiral capillary gas chromatography-mass spectrometry (GC-MS) with selected ion monitoring (SIM). N,O-Di-trifluoroacethyl (TFA) derivatization was accomplished in a dried hydrochloride extract of plasma (minimum quantity of 0.2 mL). An SIM GC-MS method with a β-cyclodextrin chiral capillary column allowed the successful and simultaneous detection of each TFA-derivatized stereoisomer of EP, NE, PEP, PNE, and an internal standard (IS; S-(+)-ethylamphetamine). Each TFA-drivatized stereoisomer was identified using four mass fragment ions (m/z 140, 154, 168, and 230). The TFA-derivatized stereoisomers of EP, NE, PEP, PNE, and IS were separated completely and were detected with sufficient sensitivity. The assay allowed the stereoisomers to be determined in a linear range of 12.5-1250 ng/mL for the EP stereoisomers and a linear range of 5-1250 ng/mL for the PEP, NE, and PNE stereoisomers. The detection limits were 7.5 ng/mL for the EP stereoisomers and 2.5 ng/mL for the PEP, NE, and PNE stereoisomers. The intra- and interday precisions were less than 5.9% and 8.2%, respectively. This chiral capillary SIM GC-MS method was sufficiently effective in the analysis of plasma from users of over-the-counter cold medicines and was also fully applicable to the plasma analysis of guinea pigs following their treatment with racemic EP.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous chiral analysis of methamphetamine and related compounds by capillary electrophoresis/mass spectrometry using anionic cyclodextrin.

A capillary electrophoresis/mass spectrometry method for the simultaneous chiral analysis of enantiomers of methamphetamine (MA), amphetamine (AP), dimethylamphetamine (DMA), ephedrine (EP), norephedrine (NE) and methylephedrine (ME) in urine has been developed. The background electrolyte was 1 M formic acid (pH 1.7). Using 0.85 mM heptakis(2,6-diacethyl-6-sulfato)-beta-cyclodextrin as the chir...

متن کامل

Development and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry

The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...

متن کامل

Enantiomeric determination of ephedrines and norephedrines by chiral derivatization gas chromatography-mass spectrometry approaches.

Concerned with variations in abuse potential and control status among various isomers of ephedrines and norephedrines, this study was conducted to develop an effective method for the simultaneous analysis of eight ephedrine-related compounds along with structurally similar cathinones. Among various approaches studied, a 60-m HP-5MS (0.25 mm i.d., 0.25 microm film thickness) was successfully use...

متن کامل

Comparative Pharmacokinetics of Berberine, Palmatine and Jatrorrhizine in Rat Plasma after Oral Administration of Rhizoma coptidis and Zuojinwan Using Liquid Chromatography-Tandem Mass Spectrometry

A selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of berberine, palmatine and jatrorrhizine in rat plasma. Target compounds, together with the internal standard (metronidazole), were extracted from rat plasma samples by protein precipitation with acetonitrile-methanol (1:2, v/v). Chromatography was carried out using a ...

متن کامل

Enantiomeric separation and quantification of ephedrine-type alkaloids in herbal materials by comprehensive two-dimensional gas chromatography.

The separation of ephedrine-type alkaloids and their enantiomers in raw herbs and commercial herbal products was investigated by carrying out enantioselective separation in the first-dimension column (containing beta-cyclodextrin as the chiral selector) of a comprehensive two-dimensional gas chromatography (GC x GC) system, whereas a polar polyethylene glycol capillary column was used for separ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 36 2  شماره 

صفحات  -

تاریخ انتشار 2012