چکیده

BACKGROUND The aim of the present study was to evaluate the cyclic fatigue resistance of Mtwo NiTi rotary instruments after clinical use by 1 experienced and 1 novice operator. MATERIAL/METHODS Cyclic fatigue testing of instruments was performed on tapered artificial canals with a 5 mm radius of curvature and 60° angle of curvature. Twenty Mtwo instruments for each size were selected and divided into 2 groups: group A consisted of 10 instruments of each size used for shaping 10 root canals in molar teeth of patients by an experienced operator; group B consisted of 10 instruments of each size used for shaping 10 root canals in molar teeth of patients by a novice operator. Instruments were rotated until fracture occurred and the numbers of cycles to failure (NCF) were recorded. Data obtained were subjected to an independent sample t-test to determine statistical differences. The significance was determined at a 95% confidence level. RESULTS No statistically significant difference (P<0.05) was noted between the instruments of groups A and B for all sizes. More instruments with visible signs of plastic deformation were identified for the novice operator. CONCLUSIONS The clinical use of Mtwo NiTi rotary instruments by a novice operator did not significantly affect the cyclic fatigue resistance when compared with the control group of the same instrument sizes used by an experienced operator. It can be concluded that novice operators can use these instruments safely under the recommended technical guidelines.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of cyclic fatigue and torsional resistance in reciprocating single-file systems and continuous rotary instrumentation systems.

As compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were s...

متن کامل

Is the reciprocating movement per se able to improve the cyclic fatigue resistance of instruments?

AIM To compare cyclic fatigue resistance of two geometrically similar nickel-titanium instruments, used in conditions similar to clinical use in reciprocating and continuous rotary motion. METHODOLOGY Four groups of eighteen instruments each, Reciproc(®) files sizes ISO 25 and 40 (R25 and R40) and Mtwo(®) files sizes ISO 25 and 40 (M25 and M40), were tested in reciprocating and continuous rot...

متن کامل

Shaping Ability of NiTi Rotary versus Stainless-Steel Hand Instruments in Curved Root Canals of Extracted Teeth

Introduction: The purpose of this in-vitro study was to compare shaping ability of NiTi rotary Mtwo and FlexMaster with stainless steel hand K-Flexofile in curved root canals of extracted teeth. Materials and Methods: Mesiobuccal canals of 45 mandibular molar teeth were balanced into three groups of 15 each, with respect to the Schneider angle, canal access angle, height, dis-tance and radiu...

متن کامل

Effect of Deep Cryogenic Treatment on Cyclic Fatigue of Endodontic Rotary Nickel Titanium Instruments

INTRODUCTION Cyclic fatigue is the common reason for breakage of rotary instruments. This study was conducted to evaluate the effect of cryogenic treatment (CT) in improving the resistance to cyclic fatigue of endodontic rotary instruments. METHODS AND MATERIALS In this in vitro study, 20 RaCe and 20 Mtwo files were randomly divided into two groups of negative control and CT. CT files were st...

متن کامل

Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization

NiTi instruments have a high risk of separation due to torsional or flexural fatigue (cyclic fatigue). Chemomechanical preparation, cleaning procedures, chemical disinfection and sterilization cause the corrosion of endodontic instruments that may weaken the fracture resistance of the instruments. Objective To assess the effects of NaOCl immersion and autoclave sterilization on the cyclic fatig...