Light intensity decay in quartz-tungsten-halogen polymerization units.
نویسندگان
چکیده
OBJECTIVES The aim of this study was to determine the effect of ageing on the light intensity of quartz-tungsten-halogen (QTH) polymerization units in dental schools and dental clinics. MATERIALS & METHODS Two dental schools and multiple public health dental clinics were visited and the light intensity of curing units was assessed. The age, make, model and service history were recorded. A calibrated radiometer (range 0-1000 nm) was used to measure the light intensity of 171 QTH units. At the end of each visit, the team members provided each dental clinic with a verbal report of the test results and recommendations on maintenance of light polymerization units. RESULTS The 171 units tested were from seven different manufacturers. The mean light intensity was 373.1 mW/cm(2), the lowest intensity being 95.3 and the highest 526.60 mW/cm(2). Only 29 QTH units recorded more than 500 mW/cm(2); 102 units showed readings that ranged between 300 and 500 mW/cm(2) and 39 units recorded readings below 300 mW/cm(2). It was not able that one unit had light intensity reading of less than 100 mW/cm(2). The age distribution was as follows: 35 units were more than 10 years old, 79 were from 5 to 10 years old and 57 were less than 5 years old. There was a high statistical significant relation between the mean light intensity and age (P = 0.001). CONCLUSION Light intensity values used in some dental clinics were to be found lower than what is recommended for optimum polymerization of resin-based composite restorations. Awareness among dentists of the value of QTH light curing units and their commitment to care and maintenance are crucial to achieving optimum restoration properties. How to cite this article: Al-Samadani KH, Al-Dharrab A, Wahbi MA , Algizani L. Light Intensity Decay in Quartz-Tungsten-Halogen Polymerization Units. J Int Oral Health 2013; 5(1):23-30.
منابع مشابه
Effect of inhomogeneity of light from light curing units on the surface hardness of composite resin.
This study investigated the characteristics of output light from different types of light curing units, and their effects on polymerization of light-activated composite resin. Three quartz-tungsten-halogen lamps, one plasma arc lamp, and one LED light curing unit were used. Intensity distribution of light emitted from the light guide tip was measured at 1.0-mm intervals across the guide tip. Di...
متن کاملConventional and high-intensity halogen light effects on polymerization shrinkage of orthodontic adhesives.
The objectives of this study were to compare the polymerization shrinkage of three orthodontic adhesives. In addition we wanted to determine the effectiveness of the high-intensity quartz tungsten halogen (HQTH) in curing orthodontic adhesives on polymerization shrinkage with that of the quartz tungsten halogen (QTH). A total of 120 glass ring molds were prepared using a low-speed saw. The inte...
متن کاملComparative evaluation of the effect of Light Emitting Diode (LED) and Quartz Tungsten Halogen (QTH) light curing units on color stability of Filtek Z350 XT
Introduction:Discoloration of the resin-based composites is a common problem in restorative dentistry. There are many factors associated with the discoloration of dental materials in the oral environment. The purpose of this study was to evaluate the color changes in a nano-composite cured with a quartz-tungsten-halogen (QTH) and light emitting diode (LED) unit. Methods:80 disk-shaped specim...
متن کاملEfficacy of halogen photopolymerization units in private dental offices in Toronto.
PURPOSE Light units used for polymerization of resin composites are subject to deterioration with age, and frequent maintenance is required to maintain optimal efficacy. This study examined the efficacy of quartz-tungsten-halogen light units in private dental offices in Toronto for polymerization of resin composites. MATERIALS AND METHODS One hundred dental offices met all selection criteria ...
متن کاملComparison of light transmittance in different thicknesses of zirconia under various light curing units
PURPOSE The objective of this study was to compare the light transmittance of zirconia in different thicknesses using various light curing units. MATERIALS AND METHODS A total of 21 disc-shaped zirconia specimens (5 mm in diameter) in different thicknesses (0.3, 0.5 and 0.8 mm) were prepared. The light transmittance of the specimens under three different light-curing units (quartz tungsten ha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of international oral health : JIOH
دوره 5 1 شماره
صفحات -
تاریخ انتشار 2013