Development of a capacitive chemical sensor based on Co(II)-phthalocyanine acrylate-polymer/HfO2/SiO2/Si for detection of perchlorate

نویسندگان

  • M. Braik
  • C. Dridi
  • M. Ben Ali
  • M. Ali
  • M. Abbas
  • M. Zabala
  • J. Bausells
  • N. Zine
  • N. Jaffrezic-Renault
چکیده

We report the development of a chemical sensor based on a Co(II) phthalocyanine acrylate polymer (Co(II)Pc-AP) for perchlorate anion detection. We have used two types of transducers, silicon nitride (Si3N4) and hafnium oxide (HfO2). The adhesion of the Co(II)Pc-AP on different transducers and their surface qualities have been studied by contact angle measurements. We have studied the pH effect on Al/Si/SiO2/HfO2/electrolyte capacitance values for different phosphate buffer solutions (PBS). This optimization step has allowed a sensitivity value of about 44 mV decade towards H ions. The fabricated sensors based on Si3N4 and HfO2 transducers functionalized with a Co(II)Pc-AP membrane have been characterized by C(V) measurements for different perchlorate concentrations (from 10 to 10 M). The sensor developed with the HfO2 transducer shows better performances compared to that based on Si3N4: a larger detection range (10 −7 to 10 and 10 to 10 M, respectively) and lower detection limits (10 and 10 M). The specificities of our perchlorate sensor have been tested for some interfering ions (nitrate, sulfate and carbonate).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Electrochemical Sensor Based on Novel Ion Imprinted Polymeric Nanoparticles for Selective Detection of Lead Ions

In this study, the novel surface ion-imprinted polymer (IIP) particles were prepared and applied as a electrode modifier in stripping voltammetric detection of lead(II) ion. A carbon paste electrode (CPE) modified with IIP nanoparticles and multi-walled carbon nanotubes (MWCNTs) was used for accumulation of toxic lead ions. Various factors that govern on electrochemical signals including carbon...

متن کامل

Use of laser-triggered gold nanoparticle-grafted dual light and temperature-responsive polymeric sensor for the recognition of thioguanine as anti-tumor agent

Objective(s): Today, there is an urgent need for improved sensor materials for drug sensing and effective monitoring and interventions in this area are highly required to struggle drug abuse. The present study aimed to synthesize a thioguanine-responsive sensor based on a nanocomposite consisting of AuNP-grafted light- and temperature-responsive poly butylmethacrylate-co-acrylamide-co-methacryl...

متن کامل

COBALT PHTHALOCYANINE MODIFIED CARBON PASTE ELECTRODE AS A POTENTIOMETRIC SENSOR FOR DETERMINATION OF ASCORBIC ACID

A carbon Paste electrode modified with cobalt (II) phthalocyanine (CoPC) was used as a sensitive potentiometric sensor for determination of ascorbic acid in aqueous solutions. The potential response of the electrode is a linear function of ascorbic acid concentration over the range 5 10 to 10 M (?1- 1800 µg ML ) with a Nernstian slope of 56 mV at pH 7. The limit of detection was 0.2 µg ...

متن کامل

Development of Carbon Paste Electrode/EDTA/Polymer Sensor for Heavy Metals Detection

The method used to immobilize the polymer on the Disodium ethylenediamine tetraacetate (EDTA) modified carbon paste electrode (CPE/EDTA) has proved its effectiveness for the detection and chelation of heavy metals in aqueous solution. Its complex formation with Pb(II) was examined by square wave voltammetry and cyclic voltammetry. CPE/EDTA electrodes are predisposed to the phenomenon of dissolu...

متن کامل

The Radiation Response of the High Dielectric-Constant Hafnium Oxide/Silicon System

We have explored the radiation response of the HfO2/Si system with a combination of capacitance versus voltage and electron spin resonance measurements on capacitor and bare oxide structures subjected to Co gamma irradiation and vacuum ultraviolet irradiation. Our studies have utilized both (100)Si and (111)Si substrate structures. Capacitors have been irradiated under both positive and negativ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015