Screening for Significant Refractive Error Using a Combination of Distance Visual Acuity and Near Visual Acuity

نویسندگان

  • Peiyao Jin
  • Jianfeng Zhu
  • Haidong Zou
  • Lina Lu
  • Huijuan Zhao
  • Qiangqiang Li
  • Xiangui He
چکیده

PURPOSE To explore the effectiveness of using a series of tests combining near visual acuity (NVA) and distance visual acuity (DVA) for large-scale screenings for significant refractive error (SRE) in primary school children. METHOD Each participant underwent DVA, NVA and cycloplegic autorefraction measurements. SREs, including high myopia, high hyperopia and high astigmatism were analyzed. Cycloplegic refraction results were considered to be the gold standard for the comparison of different screening measurements. Receiver-operating characteristic (ROC) curves were constructed to compare the area under the curve (AUC) and the Youden index among DVA, NVA and the series combined tests of DVA and NVA. The efficacies (including sensitivity, specificity, positive predictive value, and negative predictive value) of each test were evaluated. Only the right eye data of each participant were analysed for statistical purpose. RESULT A total of 4416 children aged 6 to 12 years completed the study, among which 486 students had right eye SRE (SRE prevalence rate = 11.01%). There was no difference in the prevalence of high hyperopia and high astigmatism among different age groups. However, the prevalence of high myopia significantly increased with the age (χ² = 381.81, p<0.01). High hyperopia was the biggest SRE factor associated with amblyopia(p<0.01,OR = 167.40, 95% CI: 75.14∼372.94). The DVA test was better than the NVA test for detecting high myopia (Z = 2.71, p<0.01), but the NVA test was better for detecting high hyperopia (Z = 2.35, p = 0.02) and high astigmatism (Z = 4.45, p<0.01). The series combined DVA and NVA test had the biggest AUC and the highest Youden Index for detecting high hyperopia, myopia, astigmatism, as well as all of the SREs (all p<0.01). CONCLUSION The series combined DVA and NVA test was more accurate for detecting SREs than either of the two tests alone. This new method could be applied to large-scale SRE screening of children, aged 6 to 12, in areas that are less developed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of visual acuity and residual refractive error after cataract surgery in patients with senile cataract by phacoemulsification

Background and Aim: Vision improvement and reduction of refractive errors are considered as important goals of cataract surgery. The purpose of this study was to evaluate residual refractive errors after cataract surgery in the patients with senile cataract in Shahid Rahimi Hospital in Khorramabad City between 2017 and 2018. Material and Methods: This cross-sectional study included 178 patients...

متن کامل

A Quantitative Investigation on the Effect of Edge Enhancement for Improving Visual Acuity at Different Levels of Contrast

Background: The major limitation in human vision is refractive error. Auxiliary equipment and methods for these people are not always available. In addition, limited range of accommodation in adult people when switching from a far point to a near point is not simply possible. In this paper, we are looking for solutions to use the facilities of digital image processing and displaying to improve ...

متن کامل

Visual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus

Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...

متن کامل

Piggyback intraocular lens implantation to correct pseudophakic refractive error after segmental multifocal intraocular lens implantation.

PURPOSE To evaluate refractive and visual outcomes of secondary piggyback intraocular lens implantation in patients diagnosed as having residual ametropia following segmental multifocal lens implantation. METHODS Data of 80 pseudophakic eyes with ametropia that underwent Sulcoflex aspheric 653L intraocular lens implantation (Rayner Intraocular Lenses Ltd., East Sussex, United Kingdom) to corr...

متن کامل

بررسی مقایسه‌ای حدت بینایی و حساسیت به کنتراست در رانندگان مراجعه‌کننده به درمانگاه چشم‌ بیمارستان فرشچیان همدان

Background and Objective: Car accidents are the second leading cause of mortality in Iran. For safe driving, drivers require minimum acceptable visual acuity. In Iran, the accepted routine test to take driving license is Snellen vision chart, which is not adequate for visual acuity determination in real and natural environment. It seems that introducing a more sensitive and specific screening t...

متن کامل

Validity of Uncorrected Visual Acuity Measured in Vision Screening Programs for Detecting Refractive Errors

Purpose: Uncorrected visual acuity is the only variable measured in vision screening programs in many countries worldwide. The aim of this study was to calculate the sensitivity, specificity, and predictive value of the uncorrected visual acuity in the screening programs for the diagnosis of refractive errors. Methods: In this cross-sectional study, of 4,157 students in the first year of primar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015