Comparison of (14)C liquid scintillation counting at NIST and NRC Canada.
نویسندگان
چکیده
An informal bilateral comparison of (14)C liquid scintillation (LS) counting at the National Research Council of Canada (NRC) and the National Institute of Standards and Technology (NIST) has been completed. Two solutions, one containing (14)C-labeled sodium benzoate and one containing (14)C-labeled n-hexadecane, were measured at both laboratories. Despite observed LS cocktail instabilities, the two laboratories achieved accord in their standardizations of both solutions. At the conclusion of the comparison, the beta spectrum used for efficiency calculations was identified as inadequate and the data were reanalyzed with different inputs, improving accord.
منابع مشابه
Standardization of 68Ge/68Ga Using Three Liquid Scintillation Counting Based Methods
A solution containing (68)Ge in equilibrium with its daughter, (68)Ga, has been standardized for the first time at the National Institute of Standards and Technology (NIST) using 3 liquid scintillation-based techniques: live-timed 4πβ -γ anticoincidence (LTAC) counting, the Triple-to-Double Coincidence Ratio (TDCR) method, and (3)H-standard efficiency tracing with the CIEMAT(1)/NIST (CNET) meth...
متن کاملDetermination of chemical and radiochemical purity of [14C] clozapine by high performance liquid chromatography and liquid scintillation [Persian]
Introduction: The mechanism of action and metabolism of clozapine, a complex drug used in psychopharmacology, is not completely understood. The effects of this compound in human body are related to some interactions with serotonin and dopamine neurotransmitter receptors. To further elucidate the mechanism of action and to support ongoing drug metabolism studies, [14C] clozapine with suita...
متن کاملA performance comparison of nine selected liquid scintillation cocktails.
Sample load capacity, sample compatibility, influence of sample load on (3)H/(14)C counting efficiency, background count rate, figure of merit, quench resistance, and sample stability for nine selected, commercially available, liquid scintillation cocktails are presented in this study. The cocktails tested are Ecoscint A, Insta-Gel Plus, OptiPhase Hisafe 3, OptiPhase Trisafe, Ready Gel, SafeSci...
متن کاملMassic Activity Ratios of the NBS/NIST Tritiated-Water Standards Issued Between 1954 and 1999
As part of the preparation and calibration of three new National Institute of Standards and Technology (NIST) tritiated-water radioactivity Standard Reference Materials (SRMs), the massic-activity (activity of the sample divided by the mass of the sample) ratios of all of the available NBS/NIST tritiated-water SRMs issued between 1954 and 1999 were measured using liquid-scintillation (LS) count...
متن کاملRevision of the NIST Standard for (223)Ra: New Measurements and Review of 2008 Data.
After discovering a discrepancy in the transfer standard currently being disseminated by the National Institute of Standards and Technology (NIST), we have performed a new primary standardization of the alpha-emitter (223)Ra using Live-timed Anticoincidence Counting (LTAC) and the Triple-to-Double Coincidence Ratio Method (TDCR). Additional confirmatory measurements were made with the CIEMAT-NI...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
دوره 109 شماره
صفحات -
تاریخ انتشار 2016