Complex gamma-ray hologram: solution to twin images problem in atomic resolution imaging.
نویسندگان
چکیده
A new technique for high fidelity three-dimensional imaging of atomic structure with gamma-ray holography is demonstrated. A complex hologram was constructed from holograms recorded for different values of the nuclear scattering amplitude on both sides of the (57)Fe Mössbauer resonance. The holographic reconstruction was applied to this complex hologram resulting in a twin-image-free image of the bcc Fe local structure. The proposed procedure allows the removal of the twin images for all real space, making gamma-ray holography an unambiguous tool for atomic and magnetic structure imaging.
منابع مشابه
Determination of Optimum Planar Imaging Parameters for Small Structures with Diameters Less Than the Resolution of the Gamma Camera
Introduction: The limited spatial resolution of the gamma camera hinders the absolute quantification of planar images of small structures. The imaged structures are affected by partial volume effects (PVEs), which can spread activity and lead to underestimation of the regional distribution. The use of optimum planar parameters reduces the impact of the limited spatial resolution of the gamma c...
متن کاملNew method for recording digital holograms
Recent noteworthy advancements in the field of incoherent digital holography (the production of 3D images) include optical scanning holography and Fresnel incoherent correlation holography (FINCH) techniques.1, 2 The latter acts as a single channel incoherent interferometer (a device that splits light into two beams and recombines them to produce an interference pattern) and does not require an...
متن کاملX-ray imaging at the nanoscale
X-ray imaging at the nanoscale Tim Salditt Institut für Röntgenphysik, Universität Göttingen X-rays deeply penetrate matter and thus provide information about the functional (interior) architecture of complex samples, from biological tissues and cells to novel composite materials. However, this potential of hard -rays in view of penetration power, high spatial resolution, quantitative contrast,...
متن کاملBremsstrahlung imaging from the liver using the Monte Carlo simulation
Introduction: Most beta and gamma radiation radioisotopes used for treatment are not suitable for imaging. The bremsstrahlung images on a conventional gamma camera helped to localize the radionuclide within and outside of the lesion. Secondary scattering of gamma rays of higher energy and bremsstrahlung causes contamination in the energy window and reducing the contrast and resolution of the im...
متن کاملSolution to the twin image problem in holography.
While holography truly constitutes an ingenious concept, ever since its invention by Gabor it has been troubled by the so-called twin-image problem limiting the information that can be obtained from a holographic record. For symmetry reasons there are always two images appearing in the reconstruction of a hologram and the unwanted out of focus twin-image obscures the object. Here we show a univ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physical review letters
دوره 86 8 شماره
صفحات -
تاریخ انتشار 2001