Pulmonary ventilation and perfusion assessed by electrical impedance tomography Experimental studies in pigs

نویسنده

  • Anneli Fagerberg
چکیده

Pulmonary ventilation and perfusion and ventilation/perfusion (V/Q) matching determine gas exchange in every lung unit in the healthy state and in the pathologically altered lung. Mismatch of V and Q lead to hypoxaemia and hypercapnia and monitoring of V/Q relations are thus important in critical illness. This thesis focuses on electrical impedance tomography (EIT) to monitor pulmonary perfusion and its relation to ventilation in physiological conditions and in endotoxinaemic acute lung injury (ALI) in a porcine experimental model. EIT is a non-invasive, non-radiant continuous monitoring technique generating images of impedance distribution changes within the thorax. Blood and air differ considerably in impedance properties, resulting in characteristic distribution images of pulmonary ventilation and perfusion respectively. The methodology of assessing global perfusion by EIT was evaluated in the healthy state during interventions resembling acute hypovolaemia and recruitment manoeuvres. The pulse synchronous amplitude of systolic impedance change, measured during apnoea, correlated to a wide range of stroke volumes measured by the pulmonary artery catheter, as an estimate of pulmonary perfusion. The methodology was expanded to include regional perfusion and its relation to ventilation by combined measurements during apnoea and ventilation, generating estimates of V/Q relations. Global EIT measurements correlated significantly to venous admixture and alveolar dead space calculated by standard methods. Regional EIT measurements of V and Q provided physiologically relevant results under dynamic conditions. The monitoring technique was applied in pigs subjected to endotoxinaemic ALI to assess changes in regional V and Q and V/Q matching. V/Q mismatch developed primarily as a result of dorsal redistribution and increased heterogeneity of perfusion. Finally, pre-treatment with the angiotensin converting enzyme (ACE) inhibitor enalapril to reduce angiotensin II levels and attenuate the inflammation and V/Q mismatch in endotoxinaemic ALI was examined, employing EIT monitoring. The investigation failed to provide support for the hypothesis that ACE inhibition could improve V/Q mismatch and thus gas exchange. In conclusion, this thesis demonstrated that the EIT technique could be used to assess global and regional pulmonary perfusion and its relation to ventilation in physiological as well as pathological conditions

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrical impedance tomography applied to assess matching of pulmonary ventilation and perfusion in a porcine experimental model

INTRODUCTION Electrical impedance tomography (EIT) can be used to measure impedance changes related to the thoracic content of air and blood. Few studies, however, have utilised EIT to make concurrent measurements of ventilation and perfusion. This experimental study was performed to investigate the feasibility of EIT to describe ventilation/perfusion (V/Q) matching after acute changes of pulmo...

متن کامل

Fuzzy Modeling of Electrical Impedance Tomography Images of the Lungs

OBJECTIVES Aiming to improve the anatomical resolution of electrical impedance tomography images, we developed a fuzzy model based on electrical impedance tomography's high temporal resolution and on the functional pulmonary signals of perfusion and ventilation. INTRODUCTION Electrical impedance tomography images carry information about both ventilation and perfusion. However, these images ar...

متن کامل

Cardiac-related impedance changes obtained by electrical impedance tomography: an acceptable parameter for assessment of pulmonary perfusion?

monitoring regional ventilation. Interest is growing to derive additional information on pulmonary perfusion and ventilation/perfusion distribution. Since signals recorded by electrical impedance tomography also contain cardiac-related impedance changes, attempts are made to evaluate them in view of perfusion. Recently in Critical Care a corresponding study applying an advanced fi ltering techn...

متن کامل

Hyperoxia affects the regional pulmonary ventilation/perfusion ratio: an electrical impedance tomography study.

BACKGROUND The way in which hyperoxia affects pulmonary ventilation and perfusion is not fully understood. We investigated how an increase in oxygen partial pressure in healthy young volunteers affects pulmonary ventilation and perfusion measured by thoracic electrical impedance tomography (EIT). METHODS Twelve semi-supine healthy male volunteers aged 21-36 years were studied while breathing ...

متن کامل

Effect of Electrode Belt and Body Positions on Regional Pulmonary Ventilation- and Perfusion-Related Impedance Changes Measured by Electric Impedance Tomography

Ventilator-induced or ventilator-associated lung injury (VILI/VALI) is common and there is an increasing demand for a tool that can optimize ventilator settings. Electrical impedance tomography (EIT) can detect changes in impedance caused by pulmonary ventilation and perfusion, but the effect of changes in the position of the body and in the placing of the electrode belt on the impedance signal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009