Characterization of estrogen-trenbolone acetate implants on tenderness and consumer acceptability of beef under the effect of 2 aging times.

نویسندگان

  • J L Igo
  • J C Brooks
  • B J Johnson
  • J Starkey
  • R J Rathmann
  • A J Garmyn
  • W T Nichols
  • J P Hutcheson
  • M F Miller
چکیده

Anabolic steroid implants are commonly used to increase growth performance and carcass leanness. The objective of this study was to determine the effects of various trenbolone acetate implants on Warner-Bratzler shear force (WBSF), slice shear force, and consumer palatability ratings for USDA Choice and Select beef strip steaks aged for 14 and 21 d from cattle implanted before slaughter. Beef steers (n = 1,740) were subjected to the following treatments: 1) nonimplanted control (CON); 2) Revalor-IS on d 0 and Revalor-S on d 70 (IS/S); or 3) Revalor-XS (RXS) on d 0, and were randomly assigned to pens within blocks. A subsample of USDA Choice (n = 82) and USDA Select (n = 81) carcasses was selected. Strip loins from these carcasses were collected, and steaks measuring 2.54 cm were fabricated and aged for 14 or 21 d postmortem. Select steaks aged 14 d from RXS cattle had decreased (P < 0.05) WBSF values compared with IS/S steaks, but CON steaks did not differ from either implant treatment. Warner-Bratzler shear force did not differ among treatments (P > 0.05) from USDA Choice steaks aged 14 and 21 d or from Select steaks aged 21 d. Consumer scores for flavor and overall liking for USDA Choice 14-d aged RXS steaks were less (P < 0.05) than CON steaks; however, there were no differences between RXS, IS/S, and CON for tenderness or juiciness, or for tenderness and overall acceptability. Select steaks aged 14 d from IS/S cattle had less (P < 0.05) tenderness, tenderness acceptability, overall acceptability, overall liking, juiciness, and flavor scores than RXS and CON steaks; however, consumers also rated RXS steaks less for tenderness, juiciness, and tenderness acceptability when compared with CON steaks. Consumer scores for overall liking, flavor, and tenderness for USDA Choice steaks aged 21 d from RXS, IS/S, and CON did not differ. However, implant affected (P < 0.05) overall liking, flavor, juiciness, and tenderness for USDA Select steaks aged 21 d. Even so, there were no differences between RXS, IS/S, and CON steaks for tenderness or overall acceptability for steaks aged 21 d, regardless of quality grade. Results indicated that tenderness differences exist among implant strategies when strip steaks were aged 14 d; however, tenderness and overall consumer acceptability were only influenced by implant in Select steaks aged 14 d. Furthermore, aging for 21 d can minimize and even eliminate implant differences in WBSF and slice shear force, as well as tenderness and overall consumer acceptability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A REVIEW OF STUDIES OF TRENBOLONE Issue 10 ACETATE USE IN BEEF CATTLE October 1990

Trenbolone acetate (TBA), the active compound in Finaplix implants, is a synthetic steroid that is used for promotion of growth of beef cattle. By itself, TBA exerts only moderate effects on growth, performance and carcass characteristics of steers and heifers. When used in combination with estrogen(E)-containing implants, TBA results in dramatically increased growth, improved feed conversion e...

متن کامل

Effect of repeated administration of combination trenbolone acetate and estradiol implants on growth, carcass traits, and beef quality of long-fed Holstein steers.

Our objective was to determine the effect of repeated use of implants on feedlot performance and carcass characteristics of Holstein cattle. Holstein steers (n = 128) weighing an average of 211 kg were blocked by weight and randomly assigned to 16 pens. At the start of the trial (d 0), pens were assigned to one of four treatments: 1) nonimplanted control (C); 2) implant on d 0, 112, and 224 (T3...

متن کامل

National beef tenderness survey - 2006: Assessment of Warner-Bratzler shear and sensory panel ratings for beef from US retail and foodservice establishments.

Beef from retail and foodservice establishments in 11 US cities was evaluated using Warner-Bratzler shear (WBS) and consumer evaluation panels. Postmortem aging times ranged from 3 to 83d for retail and 7 to 136d for foodservice with mean aging times of 22.6d and 30.1d, respectively. For retail, the three cuts from the round - top round, bottom round, and eye of round - had the highest (P<0.05)...

متن کامل

MEAT SCIENCE AND MUSCLE BIOLOGY SYMPOSIUM--implants, muscle development, and meat quality.

Anabolic implants are routinely used in the finishing phase of beef production to improve animal performance and feed efficiency. Implanting during the feedlot phase on average increases ADG 18%, feed intake 6%, feed efficiency 8%, carcass weight 5% and ribeye area 4% compared with non-implanted controls. Implants reduce the cost of beef production, which is important given current high feed co...

متن کامل

Effect of growth promotants on the occurrence of endogenous and synthetic steroid hormones on feedlot soils and in runoff from beef cattle feeding operations.

Supplements and growth promotants containing steroid hormones are routinely administered to beef cattle to improve feeding efficiency, reduce behavioral problems, and enhance production. As a result, beef cattle manure will contain both synthetic steroids as well as a range of endogenous steroids including androgens, estrogens, and progestogens. A two-year controlled study was conducted in whic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of animal science

دوره 89 3  شماره 

صفحات  -

تاریخ انتشار 2011