Compressive force applied to a manikin's head during mask ventilation.
نویسندگان
چکیده
OBJECTIVE To investigate the compressive force applied to the head during mask ventilation and determine whether this force increases in response to an attempt to correct the mask leak. METHODS The authors asked 24 participants (consultants, fellows and nurses) to administer positive pressure ventilation to a modified leak-free, term newborn manikin using a self-inflating bag (SIB) and a Neopuff T-piece device. Recordings were made before and after the participants were informed about their percentage of mask leak and asked to correct this. Airway pressure and flow were measured using a Florian monitor, and the force applied to the head was measured using a concealed custom-made load cell weighing scale. RESULTS There were no differences in the mean (SD) force applied to the head between devices used and before or after the attempt to correct the mask leak (SIB before 2215 (892) and after 2195 (989) g; Neopuff before 1949 (957) and after 2028 (909) g). There was a large variation in force with both devices before and after the attempt (coefficient of variation: SIB before 40% and after 45%; Neopuff before 50% and after 45%). There was no correlation between mask leak and the difference in force used before and after the attempt to correct the mask leak using both devices. CONCLUSION During mask ventilation of a manikin, the authors observed that large forces were exerted on the head with either an SIB or a Neopuff, but these forces did not increase during the attempt to minimise the mask leak.
منابع مشابه
Nasal ventilation is more effective than combined oral-nasal ventilation during induction of general anesthesia in adult subjects.
BACKGROUND The authors hypothesized that nasal mask ventilation may be more effective than combined oral-nasal mask ventilation during induction of general anesthesia. They tested this hypothesis by comparing the volume of carbon dioxide removed per breath with nasal versus combined oral-nasal mask ventilation in nonparalyzed, apneic, adult subjects during induction of general anesthesia. MET...
متن کاملRecurred pneumocephalus in a head trauma patient following positive pressure mask ventilation during induction of anesthesia -A case report-
Pneumocephalus is a condition which usually results from head trauma. It has been known that iatrogenic pneumocephalus can occur as a complication of positive pressure mask ventilation during induction of anesthesia or ventilatory care for head trauma patients. We report a case of mask ventilation during anesthesia induction in a 50-year-old male patient with head trauma. Initial pneumocephalus...
متن کاملSidewise mask ventilation for pediatric anesthesia.
Inhalation or intravenous anesthesia along with controlled or assisted mask ventilation is frequently used for interventions with short duration in pediatric patients, especially in surgical centers with high turnover and when laryngeal mask airways do not fit. To achieve one-handed mask ventilation the anesthesiologist has to stand behind the head, and the mask is held with one hand against th...
متن کاملThe effect of patient positions, Sound production and neck rewind on Mallampati grading and classification to predict difficult mask ventilation in patients
Aims and background: The difficulty of ventilation with masks is one of the most common causes of severe respiratory consequences in the field of anesthesia. Objective: To evaluate the effect of patient position, voice production and neck rejection on the Mallamapati grade, in order to predict the difficulty of ventilation with mask in patients. Materials and Methods: This research was of a pr...
متن کاملHemodynamic responses to insertion of the laryngeal mask airway versus Combitube
Introduction: One of the most common problems during laryngoscopy involves sympathetic system stimulation and the subsequent hemodynamic changes. It is a key measure to maintain the hemodynamic stability of patients with cardiovascular diseases during induction of anesthesia. This study attempted to compare the hemodynamic effects of laryngeal mask airway and combitube. Methods: This prospec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of disease in childhood. Fetal and neonatal edition
دوره 97 4 شماره
صفحات -
تاریخ انتشار 2012