Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine.

نویسندگان

  • Ralph Kothe
  • Wolfgang Rüther
  • Erich Schneider
  • Berend Linke
چکیده

STUDY DESIGN An in vitro biomechanical study to compare 2 different dorsal screw fixation techniques in the cervical spine with respect to primary stability and stability after cyclic loading. OBJECTIVES To investigate if the biomechanical stability is better in pedicle screw or in lateral mass fixation. SUMMARY OF BACKGROUND DATA In patients with poor bone quality who require multisegmental fixations, the current dorsal stabilization procedures in the subaxial cervical spine using lateral mass screws are often insufficient. Cervical pedicle screw fixation has been suggested as an alternative procedure, but there are still limited data available on the biomechanical differences between pedicle screw and lateral mass fixation. METHODS A severe multilevel discoligamentous instability was created in 8 human cervical spine specimens (C2-C7). Dorsal stabilization was performed with the assistance of computer navigation (SurgiGate, Medivison, Switzerland) using either lateral mass or pedicle screw fixation. In the first part of the study, primary stability was measured by means of a multidirectional flexibility test. Then, specimens were divided into 2 groups, randomized for bone mineral density. Cyclic loading was applied with sinusoidal loads in flexion/extension (1000 cycles, +/-1.5 Nm, 0.1 Hz). Mechanical behavior of the specimens was determined by a flexibility test before and after the application of cyclic loads. Data analysis was performed by calculating the ranges of motion, and statistical differences were determined with the t test for group comparison. RESULTS Pedicle screw fixation showed a significantly higher stability in lateral bending (pedicle screw range of motion 0.86 +/- 0.31 degrees; lateral mass range of motion 1.43 +/- 0.62 degrees; P = 0.037). No significant differences were seen in flexion/extension and axial rotation. After cyclic loading, the decrease in stability was less with pedicle screw fixation in all load directions. Differences in the decrease of stability were statistically significant in flexion/extension (pedicle screw 95.4 +/- 9.4%; lateral mass 70.5 +/- 9.8%; P = 0.010) and lateral bending (pedicle screw 105.3 +/- 5.0%; lateral mass 84.2 +/- 13.6%; P = 0.046), whereas there was no significant difference in axial rotation. CONCLUSIONS The major finding of the current study was the higher stability of pedicle screws over lateral mass fixation with respect to primary stability and stability after cyclic loading. From a biomechanical point of view the use of pedicle screws in the subaxial cervical spine seems justified in patients with poor bone quality and need for multisegmental fixation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anterior Transpedicular Screw-Plate System Fixation in the Lower Cervical Spine Fracture Complicated by Spinal Cord Injury: A Case Report

A multilevel contiguous fracture of the subaxial cervical spine represents the severe trauma, and anterior plate fixation with anterior transpedicular screw fixation is a new and reliable fixation pattern for the treat-ment of acute spinal cord injury (ASCI). We present a case of multilevel contiguous fractures in the lower cervical spine without obvious posterior ligamentous complex injury, bu...

متن کامل

Posterior Fixation Techniques in the Subaxial Cervical Spine

This article reviews the historical context, indications, techniques, and complications of four posterior fixation techniques to stabilize the subaxial cervical spine. Specifically, posterior wiring, laminar screw fixation, lateral mass fixation, and pedicle screw fixation are among the common methods of operative fixation of the subaxial cervical spine. While wiring and laminar screw fixation ...

متن کامل

A Novel Anterior Transpedicular Screw Artificial Vertebral Body System for Lower Cervical Spine Fixation: A Finite Element Study.

A finite element model was used to compare the biomechanical properties of a novel anterior transpedicular screw artificial vertebral body system (AVBS) with a conventional anterior screw plate system (ASPS) for fixation in the lower cervical spine. A model of the intact cervical spine (C3-C7) was established. AVBS or ASPS constructs were implanted between C4 and C6. The models were loaded in t...

متن کامل

Laminar screw fixation in the subaxial cervical spine: A report on three cases

Although laminar screw fixation is often used at the C2 and C7 levels, only few previous case reports have presented the use of laminar screws at the C3-C6 levels. Here, we report a novel fixation method involving the use of practical laminar screws in the subaxial spine. We used laminar screws in the subaxial cervical spine in two cases to prevent vertebral artery injury and in one case to min...

متن کامل

The long time follow-up of craniovertebral junction fixation in patients with rheumatoid arthritis

BACKGROUND Rheumatoid arthritis (RA) can have very destructive effects, especially in the cervical spine. Bone quality is poor in these patients. The purpose of this study is to evaluate the feasibility of fusion and accuracy of fluoroscopy in cervical transpedicular fixation (CPF) in a standardized clinical protocol for RA patients. MATERIALS AND METHODS 96 pedicles of 15 patients operated b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Spine

دوره 29 17  شماره 

صفحات  -

تاریخ انتشار 2004